  • Page 2: Table Of Contents

    Contents Contents Recycling and disposal..... 12 Guarantee and customer Safety ..........3 service ........12 Action-related warnings ....3 Guarantee........12 Intended use ........3 Customer service......12 General safety information..... 4 Appendix ..........13 Notes on the documentation ..7 Troubleshooting ......
  • Page 3: Safety

    Safety 1 1 Safety ral heating installations and for hot water generation. 1.1 Action-related warnings Intended use includes the fol- Classification of action-re- lowing: lated warnings – observance of the operating The action-related warnings instructions included for the are classified in accordance product and any other system with the severity of the pos- components...
  • Page 4: General Safety Information

    1 Safety Improper use of any kind is ▶ Do not use any electrical prohibited. switches, mains plugs, door- bells, telephones or other 1.3 General safety communication systems in information the building. 1.3.1 Installation by skilled ▶ If it is safe to do so, close the tradesmen only emergency control valve or The installation, inspection,...
  • Page 5 Safety 1 1.3.5 Risk of death from ▶ Do not alter the safety escaping flue gas devices in any way. ▶ Do not damage or remove If you operate the product with any seals on components. an empty condensate siphon, ▶...
  • Page 6 1 Safety ▶ Faults and damage should 1.3.13 Risk of material be immediately rectified by a damage caused by frost competent person. ▶ Adhere to the maintenance ▶ Ensure that the heating in- intervals specified. stallation always remains in operation during freezing con- 1.3.11 Risk of corrosion ditions and that all rooms are damage due to...
  • Page 7: Notes On The Documentation

    Notes on the documentation 2 2 Notes on the 3.2 Design of the product documentation 2.1 Observing other applicable documents ▶ You must observe all operating instruc- tions enclosed with the system compon- ents. 2.2 Storing documents ▶ Keep this manual and all other applic- able documents safe for future use.
  • Page 8: Description Of The Display

    4 Operation 4 Operation 8 DHW mode 10Heating flow tem- perature buttons 9 Heating mode 4.1 Starting up the product ) and 4.1.1 Opening the isolator devices Conditions: The competent person who installed 3.4 Description of the display the product will explain where the isolator devices are and how to handle them.
  • Page 9: Filling The Heating Installation

    Operation 4 4.3 Filling the heating installation 4.4 Selecting the operating mode Caution. Note After every ignition, the product Risk of material damage due runs in "Heating + hot water" to heating water that is ex- mode. tremely calciferous or corros- ive or contaminated by chem- The button lights up when the op- icals.
  • Page 10: Setting The Heating Flow Temperature

    4 Operation 4.7 Frost protection Conditions: Hot water temperature: < 50 ℃ – mode is shown on the display. 4.7.1 The product's frost protection Conditions: Hot water temperature: ≥ 50 ℃ function – mode is not shown on the The frost protection function switches on display.
  • Page 11: Troubleshooting

    Troubleshooting 5 6 Care and maintenance Conditions: If you are away from home for several days, With controller 6.1 Maintenance ▶ Program the number of days you will An annual inspection and biennial main- be away in the controller to activate the tenance of the product carried out by a frost protection devices.
  • Page 12: Decommissioning

    (e.g. holiday), you dress that is provided on the back page, or should also close the gas isolator cock you can visit www.glow-worm.co.uk. and the cold water stop cock. 7.2 Permanently decommissioning the product ▶...
  • Page 13: Appendix

    Appendix Appendix A Troubleshooting Fault Cause Remedy Building gas isolator cock closed Open the building-side gas isol- ator cock Building power supply switched off Switch on building power supply On/off button on product switched off Switch on the on/off button on the product The heating flow temperature is set Select the required operating...
  • Page 14 Appendix Fault Cause Remedy The display shows Fault Press the fault clearance key (Re- set) and wait for five seconds. If the fault persists, in- form a competent person. The display shows Low water pressure in the system Add treated water If the problem occurs again: In- and the pressure form the competent person...
  • Page 16 Publisher/manufacturer Glow-worm Nottingham Road ‒ Belper ‒ Derbyshire DE56 1JQ © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent. The energy you need...