Figure 1-54 Checking the reliability
The procedure for testing a crossover cable is the same as that for testing a straight-through
cable except for the sequence in which the indicators turn on. You need to refer to the wire
connections of a crossover cable.
The Ethernet cable is qualified if the indicators turn on in the following sequence:
At the master (left) section of the tester, the indicators turn on in the sequence of 1-8-G. At the
slave (right) section of the tester, the indicators turn on in the sequence of 3-6-1-4-5-2-7-8-G.
Otherwise, the Ethernet cable is unqualified.
Figure 1-55 Testing the connection of an Ethernet cable
Issue Draft A (2016-03-30)
NOTE
If a tester is not available, you can use a multimeter to perform a simple test, as shown in
Huawei Proprietary and Confidential