Technical Information
3.18
Fault Code FE 40 Flashes
Cause:
Incorrect model programming.
Remedy:
Check the model programming and program the correct model as necessary
(refer to Section 010-4.1).
3.19
Fault Codes FE 41, FE 42
Cause:
Defective NTC on heat sink of left power electronic (1A3).
Remedy:
Replace the left power electronic; see Section 010-4.9.
3.20
Fault Codes FE 43, FE 44
Cause:
Defective NTC on heat sink of right power electronic (2A3).
Remedy:
Replace the right power electronic (2A3); refer to Section 010-4.9.
3.21
Fault Code FE 45
Cause:
Defective NTC on heat sink of middle power electronic (3A3).
Remedy:
Replace the middle power electronic (3A3); refer to Section 010-4.9.
3.22
Fault Codes FE 51, FE 52, FE 53, FE 54, FE 55
Cause:
PTC for one of the burners is defective (refer to Table 010-8).
Remedy:
1. Check the appropriate PTC. For resistance values, see Table 010-2.
2. Replace the appropriate burner with PTC, if necessary; see Section 010-4.7.
Cause:
Contact fault.
Remedy:
Check plug contacts.
Cause:
Power electronic fault.
Remedy:
1. Disconnect and reconnect power.
2. Replace the power electronic; see Section 010-4.9 (depending on which
electronic is connected to the affected burner).
3.23
Fault Code FE 60
Cause:
34