Upon completion of part replacement, ensure all retaining screws are securely tightened, all
"O" rings are in place and not damaged, and all wires are securely connected.
When installing the main cover ensure the gasket is seated in the cover flange groove, the
flange area is not corroded and the surface is not scarred and that no wires can be trapped
under the cover flange. Ensure the four cover bolts screws are secure by applying 17.7±1.77
in-lbs or 2.0±0.20 N*m.
For assistance, contact the nearest sales office, your local representative or email
svisupport@ge.com. Visit our web page at
Maintenance Connection
9
The electronics module is protected by a plastic snap on cover. A keyed eight position
connector resides under the cover. This interface is only used during manufacturing, repair or
overhaul. It is not intended for field use and has been designed to prevent connection to field
wiring. It is not intended for customer use.
Copyright 2015 as an unpublished trade secret. This document and all information herein is the property of Dresser Flow
Technologies, Dresser Inc. It is confidential and must not be made public or copied and is subject to return upon demand.
84 | =GE Oil & Gas
ES-761 Rev F