Download Print this page

Replacing The Batteries - EPH Controls RFPi2 Operating Instructions

Room thermostat wireless

Advertisement

TRFPi2 Room Thermostat
9. Setting the date, time and operating mode
Set
Press the
button once. 'Set Year' will appear on the screen.
Press the
or
buttons to adjust the year.
Press the
or
buttons to adjust the month.
Press the
or
buttons to adjust the day.
Press the
or
buttons to adjust the hour.
Press the
or
buttons to adjust the minute.
Press the
or
buttons to adjust from 5/2d to 7d or 24h mode.
Press the
button or wait 30 seconds and the thermostat will return to
normal operation.
10. Factory program setting
P1
P2
Mon-Fri
21˚C
18˚C
08:00
10:00
Sat-Sun
21˚C
18˚C
P1
P2
Mon-Fri
21˚C
18˚C
08:00
10:00
Sat-Sun
21˚C
18˚C
P1
P2
Everyday
21˚C
18˚C
11. Adjusting the program settings for 5/2d
Set
Press the
button twice.
Programming for Monday to Friday is now selected.
Press the
or
buttons to adjust the P1 time. Press the 'OK' button.
Press the
or
buttons to adjust the P1 temp. Press the 'OK' button.
Repeat this process to adjust P2 to P6 times and temperatures.
Set
Press the
button.
Programming for Saturday to Sunday is now selected.
Press the
or
buttons to adjust the P1 time. Press the 'OK' button.
Press the
or
buttons to adjust the P1 temp. Press the 'OK' button.
Repeat this process to adjust P2 to P6 times and temperatures.
Press the
button to return to automatic mode.
If 7 D mode is selected, you can program each day of the week with 6
individual times and temperatures.
If 24H mode is selected, you can only program each day of the week with the
same 6 times and temperatures.
12. Temporary override (Manual)
Press the
or
buttons to adjust the temperature setpoint.
'Manual' will appear on the screen.
Press 'OK' or after 5 seconds the thermostat will operate in this temporary
override.
Press the
button to return to automatic mode.
13. Permanent override (Hold)
Press the '+1hr' button for 3 seconds.
'Hold' will appear on the screen.
Press the
or
buttons to adjust the temperature setpoint.
Press 'OK' or after 5 seconds the thermostat will operate in this permanent
override.
Press the
button to return to automatic mode.
Press the 'OK' button.
Press the 'OK' button.
Press the 'OK' button.
Press the 'OK' button.
Press the 'OK' button.
5 / 2d
5/2D
P3
P4
P5
P6
21˚C
18˚C
21˚C
16˚C
12:00
14:00
17:30
23:00
21˚C
18˚C
21˚C
16˚C
7D
P3
P4
P5
P6
21˚C
18˚C
21˚C
16˚C
12:00
14:00
17:30
23:00
21˚C
18˚C
21˚C
16˚C
24H
P3
P4
P5
P6
21˚C
18˚C
21˚C
16˚C
Wireless
14. +1hr Boost function
Press the '+1hr' button once.
Press the
or
Press the 'OK' button.
The thermostat will operate in this mode for one hour before returning to
automatic mode.
To cancel the boost mode at anytime, press the
15. Adjusting the switching di erential
Press the 'OK' and '+1hr' buttons for 5 seconds.
'H On 0.4˚C' will appear on the screen.
Press the
or
Press the 'OK' button to return to normal operation.
16. To connect the TRFPi2 thermostat to the RF1A
receiver
Please note, If you are installing a CombiPack2 the TRFPi2 thermostat and
the RF1A receiver will have a pre-established RF connection so it is not
necessary to carry out the RF connection process below.
On the RF1A receiver:
Press the
button. The red and green light will begin to ash.
Connect
On the TRFPi2 thermostat:
Press the
Connect
The thermostat will begin to search through the RF channels.
Once an RF connection has been established the thermostat will show 'r01'
on the LCD screen.
Press the 'OK' button to nish the process.
The thermostat is now connected to the RF1A receiver.
'RF Connect' appears on the screen.
17. To disconnect the TRFPi2 thermostat from the
RF1A receiver
On the TRFPi2 thermostat;
Press the
Connect
The thermostat will begin to search through the RF channels.
Press and hold the
'AdL' & 'AdH' will ash intermittently on the screen of the thermostat.
Press the 'OK' button twice to complete the unpairing process.
The thermostat TRFPi2 is now disconnected from the receiver RF1A.
Note: RF Connect may remain on the screen for a couple of minutes.
On the RF1A
Press the
button and immediately press the
RESET
The red and green lights will ash quickly followed by a solid red light.
The RF1A receiver is now disconnected from the TRFPi2 thermostat.
18. Battery low warning
When the batteries are almost empty, the
to ash on the screen.
The batteries must now be replaced or the unit will shut down.

19. Replacing the batteries

Slacken the fastening screw on the bottom of the
thermostat with a philips head screwdriver.
The thermostat is hinged and can be opened 180
degrees.
Replace the batteries with 2 x AA Alkaline batteries.
Close the thermostat and tighten the fastening screw.
Page 2 of 2
Operating Instructions
button to select your desired boost temperature.
button or the +1hr button.
buttons to adjust from 0.2, 0.4, 0.6, 0.8 or 1C.
button.
button.
standby button for 10 seconds.
Connect
symbol will begin
0.4˚C
button.

Advertisement

loading
Need help?

Need help?

Do you have a question about the RFPi2 and is the answer not in the manual?