RFRP Room Thermostat
Contents
1.

Factory default settings

2.
Speci cations & wiring
3.
Mounting
4.
Installation
5.
Frost protection
6.
LCD symbol / buttons description
7.
Resetting the thermostat
8.
Keypad lock and unlock
9.
Setting the date, time and operating mode
10. Factory program settings
11. Adjusting the program settings for 5/2d
12. Copy Function
13. Temporary override
14. Permanent override
15. Boost function
16. Holiday function
17. To connect the RFRP thermostat to an RF1A receiver
18. To disconnect the RFRP thermostat from an RF1A receiver
19. Backlight mode selection
20. Battery low warning
21. Replacing the batteries
1. Factory default settings
Temperature indicator:
Switching di erential:
In built frost protection:
Clock:
Keypad lock:
Operating mode:
2. Speci cations & wiring
Power supply:
Power consumption:
Battery replacement:
Temp. control range:
Ambient temperature:
Dimensions:
Temperature sensor:
Temperature indication:
Switching di erential:
Frost protection:
3. Mounting
The mounting height should be 1.5 meters above the oor level.
The thermostat should be wall mounted in the room where the heating is to
be controlled.
The place of installation should be chosen so that the sensor can measure the
room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other
heating / cooling sources when mounted.
The unit can be tted to:
4. Installation
Lower the ap at the front of the thermostat.
There is a battery compartment located below the buttons.
Using your 2 thumbs, apply pressure and pull downwards to remove the cover.
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment.
°C
0.4°C
5°C - Not adjustable
24 hours
O
5/2 day
2 x AA Alkaline Battery
2 mW
Once a year
5 ... 35°C
0 ... 50°C
130 x 99 x 25mm
NTC 10K Ohm @ 25°C
˚C
0.4˚C
Only operational in OFF mode
1. Recessed conduit boxes.
2. Directly on walls.
3. Table mounting with stand provided.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu ,
Cork, T12 W665, Ireland
sales@ephcontrols.com www.ephcontrols.com
Wireless
5. Frost protection
Frost protection is built into this thermostat.
It is pre xed at 5°C and is not adjustable.
It will only be activated when the thermostat is in the OFF mode and the
room temperature falls below 5°C.
6. LCD Symbol / button description
6.1 LCD Symbol description
Current program
Day / Month
Current Time
(Boost to time)
6.2 Button description
Automatic
mode
(Back)
Manual
mode
O mode
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
sales@ephcontrols.co.uk www.ephcontrols.co.uk
Page 1 of 3

Operating Instructions

CAUTION!
The thermostat must not be left unsupervised
when open. (Prevent non specialists and especially
children from gaining access to it.)
Only quali ed electricians or authorised service
sta are permitted to open the thermostat.
If the thermostat is used in a way not speci ed by
the manufacturer, its safety may be impaired.
Important: Keep this document
Prior to setting the thermostat, it is neccessary to
complete all required settings described in this section.
5°C
Temperature
Day of the week
Operating mode
OK
AUTO
MAN
OFF
PROG
TIME
HOL
COPY
BOOST
Program mode
Set Date/ Time
Battery low symbol
Wireless symbol
Heating on symbol
Keypad lock symbol
Set point increase
Wireless connect button
Set point decrease
Reset button
OK con rm button
Boost mode
Copy function
Holiday mode

Advertisement

loading
Need help?

Need help?

Do you have a question about the RFRP and is the answer not in the manual?

Questions and answers

Janette Merilion
January 26, 2025

CHANGING THE DAY

1 comments:
Mr. Anderson
February 10, 2025

Press the ‘HOL’ button, then ‘HOLIDAY FROM’ will appear on the screen. Use the or buttons to adjust the day.

This answer is automatically generated

Steve Jones
March 4, 2025

How do I change the batteries on my EPH RFRA - the temperature isn't stopping at the set limit.

1 comments:
Mr. Anderson
March 4, 2025

The manual mentions "Replacing the batteries" but does not provide specific steps for changing them. However, it states that the RFRP thermostat uses 2 x AA alkaline batteries and should be replaced once a year when the battery low symbol begins to flash.

This answer is automatically generated

Ursula
March 13, 2025

How to turn on

Summary of Contents for EPH Controls RFRP

  • Page 1: Operating Instructions

    Important: Keep this document 15. Boost function 16. Holiday function 17. To connect the RFRP thermostat to an RF1A receiver 18. To disconnect the RFRP thermostat from an RF1A receiver Prior to setting the thermostat, it is neccessary to 19. Backlight mode selection complete all required settings described in this section.
  • Page 2: Resetting The Thermostat

    Page 2 of 3 Operating Instructions RFRP Room Thermostat Wireless 11. Adjusting the program settings for 5/2d 7. Resetting the thermostat Press the ‘PROG’ button once. It is necessary to reset the thermostat prior to initial programming. Programming for Monday to Friday is now selected.
  • Page 3: Boost Function

    21. Replacing the batteries receiver Please note, If you are installing a CombiPack4 the RFRP thermostat and the Lower the ap at the front of the thermostat. RF1A receiver will have a pre-established RF connection so it is not necessary There is a battery compartment located below the buttons.