7 Appx.1: Types of Backup Data
Correspondence between absolute position data and parameters
Correspondence between absolute position data and I/O parameter #10000s is shown below.
#
Name
10001
absfint
Absolute position setting completed I/O tempo
E0 The absolute position error saved when the basic
10002
SV077
position was set.
R0 The multi-rotation counter value of the detector
10003
SV078
saved when the basic point was set.
P0 The position in one rotation of the detector saved
10004
SV079
when the basic point was set.
P0 The position in one rotation of the detector saved
10005
SV080
when the basic point was set.
The distance from the machine basic position to the
10006
absg
first grid point (cunit unit).
SV077 to SV080
10007
abssum1
Checksum (:absn abs1x absg)
SV077 to SV080
10008
abseor1
EOR (:absn abs1x absg)
10009
abssum2 Parameter checksum
10010
abseor2
Parameter EOR
10011
absbase Zero point (micro) (cunit unit)
Details
103
Timing of Updating
When the power is turned OFF and ON af-
ter changing a parameter related to abso-
lute position detection.
When the status changes to "Completed"
during the initialization procedure.
The value in the #2 "Zero point" of [Mainte]
- [Absolute Position Setting] screen. Up-
dated by screen input.