7.1.4.1 Connecting Boards to Ethernet

LIM/MGI/MGI64/MP10/MP11/4SWM board can be connected to Ethernet by using an
Ethernet cable
LIM Board-All ports(P1~P16)
4SWM Board-Line Ports(P1~P4)
MP10/11, MGI16/MGI64 Board-LAN Port
Pin No.
Function
Tx+

7.1.5 Connecting to a Door Phone and a Door Lock

Connect a door phone and a door lock to the OfficeServ 7100 system by using a Door
Phone Interface Module(DPIM). Connect a pair of #24 AWG or #26 AWG cables to the
LINE port of DPIM and the ports of 8DLI/16DLI2/8COMBO/4DLM board of the
OfficeServ 7100 system.
Connecting to 8DLI/16DLI2/4DLM Boards
Pin No.
Function

Figure 7.9 RJ-45 Port of 8DLI/16DLI2/8COMBO/4DLM Boards (for Door Phone)

1) Connect the Door port of DPIM and the line port of DOOR BOX port.
2) When using an automatic door lock, connect the Lock port of the DPIM and the door
phone contact point to the door lock.
The door lock contact point is designed to control low-voltage relay and uses 24 VDC and
100 mA.
MMC Related
MMC 211 is used to assign call numbers to door phones.
© SAMSUNG Electronics Co., Ltd.
1
2
3
Tx-
Rx+

Figure 7.8 RJ-45 Port of Ethernet Connection Board

1
2
3
-
-
-
OfficeServ 7100 Installation Manual
RJ-45 Port
4
5
-
-
4
5
DLI TIP
DLI
RING
6
7
8
Rx-
-
6
7
8
-
-
-
-
7-7