Power Readings
This section is displayed for server blades and Synergy compute modules.
Present Power Reading
The most recent power reading from the server.
Although this value is typically equal to the sum of all active power supply outputs, there might be
some small variance as a result of reading the individual power supplies. This value is a guideline
value and is not as accurate as the values presented on the Power Management pages. For more
information, see Viewing server power usage on page 149.
Power Microcontroller
This section is displayed for server blades and Synergy compute modules.
Firmware Version
The firmware version of the power microcontroller.
The server must be powered on for the iLO firmware to determine the power microcontroller firmware
version.
Battery Backup Unit details
The following details are displayed on nonblade servers that support a battery backup unit:
•
Bay—The bay where the battery backup unit is installed.
•
Present—Whether a battery backup unit is installed. The possible values are OK and Battery Failed,
and Replace Battery.
•
Status—The battery backup unit status. The possible values are OK, Degraded, Failed, or Other.
•
Charge—The battery backup unit charge level (percent). The possible charging status values are
Fully Charged, Discharging, Charging, Slow Charging, and Not Charging.
•
Serial Number—The battery backup unit serial number.
•
Capacity—The battery backup unit capacity (watts).
•
Firmware—The installed battery backup unit firmware version.
Smart Storage Battery details
The following details are displayed on servers that support the Smart Storage Battery.
•
Index—The battery index number.
•
Present—Whether a battery is installed. The possible values are OK and Not Installed.
•
Status—The battery status. The possible values are OK, Degraded, Failed, or Other.
•
Model—The battery model number.
•
Spare—The part number of the spare battery.
•
Serial Number—The battery serial number.
•
Capacity—The battery capacity.
•
Firmware—The installed battery firmware version.
Power Readings
161
Need help?
Do you have a question about the HPE iLO 5 and is the answer not in the manual?
Questions and answers