50Hz voltages. The unit will autoswitch to either of these voltages 2. Do Not Touch The PR-4Zi With Wet Hands – Do not handle the PR-4Zi or power cord when your hands are wet or damp. If water or any other liquid enters the PR-4Zi cabinet, take the PR-4Zi to a qualified service person for inspection.
Figure 1. Use high quality cables that are as short as possible to keep signal integrity intact. port allows the PR-4Zi to be controlled by touch panels or other automation devices that have an RS-232 interface. Optional Russound PCK or PCK-IR Keypads provide easy remote operation of the PR-4Zi.
CONNECTING AMPLIFIERS Connect the Zone Output of each PR-4Zi zone to one line input of a multichannel amp. Figure 2 shows a connection to the Russound DPA-6.12 Twelve Channel Audio Amplifier. (Figure 2 also shows a trigger connection, discussed on p. 6.) Figure 2 –...
PEAKER MPLIFIED NPUT COMMON AND ZONE TRIGGER OUTPUTS The PR-4Zi provides four Zone-Specific and one Common +12VDC trigger outputs (Figure 4). The Zone-Specific triggers are turned on when the corresponding zone is on. The Common trigger is turned on when any zone is on. All trigger out- puts are turned on during a page.
Wiring Instructions CONNECTING VIDEO MONITORS Each PR-4Zi zone has a composite video output to allow viewing video from any of six A/V sources. Connect monitors as shown in Figure 5 using RG6U cable with RCA type connectors. If more than two monitors are being used in a zone, a composite video distribution amplifier is recommended.
FIXED ZONE LINE OUT: CREATING SUBZONES The PR-4Zi has six buffered, fixed-level audio/video outputs as shown previously in Figure 1 (p. 4). When set to FIXED ZONE LINE OUT (Figure 7), the last four outputs can be used to create subzones of each main zone.
PAGING TRIGGER OUTPUT The PR-4Zi is equipped with a +12V paging trig- ger output (Figure 8) that switches on during a page. This output can be used to trigger an external amplifier, muting device, or other peripheral associated with paging. (Paging peripherals are discussed on page 14.)
Control Functions Figure 9 – PR-4Zi control functions OWER ELECT POWER – Controls power to entire system. IR Receiver – Provides IR control for Zone 1. ZONE SELECT – Selects current zone (1-4). ZONE SELECT Indicators – Shows current zone.
PRESET PROCEDURE PRESET recalls settings for the current zone pre- viously stored in memory. A preset can be recalled at the PR-4Zi front panel, on a PCK(IR) keypad, or via the PRC-1 remote control. Control Functions 1. Select a zone using ZONE SELECT.
Peripheral Devices PCK(IR) KEYPADS Each of the PR-4Zi’s zones can be remotely operated by a keypad or IR device. There are four keypad ports on the rear panel. Each port accommodates as many as four Russound PCK(IR) keypads (4 per zone). Wire the PCK(IR)
PCK(IR) KEYPAD CONTROL FUNCTIONS Infrared Receiver – Receives IR commands from Russound PRC-1 remote or a source component’s remote. (PCK IR only) SYSTEM ON – Turns all zones on. NOTE: The system on button will also flash to confirm IR reception.
Page 14
Peripheral Devices DSC/DAN KEYPADS Once the PCK(IR) keypads have been wired, con- nect the DSC keypad’s 16-pin header to the 16- pin receptacle on the side of the main keypad (see Figure 1a and 1b). Be sure to keep the cor- rect pin alignment.
Page 15
IKP-1 INFRARED KEYPAD PROGRAMMER The IKP-1 is a programmer used to simplify and speed up the IR programming for the DAN and DSC IR learning keypads. Learning keypads that can be used with the programmer have a plug located at the front left. Refer to IKP-1 Instruction Manual for complete instructions.
SPG PAGING MODULE The Russound SPG provides "push-to-talk" opera- tion. Use 22-24 AWG twisted pair shielded wire to connect the SPG to the PR-4Zi page input as shown in Figure 15. PTM-1 PAGING MODULE The Russound PTM-1 is a signal-sensing paging...
IR EMITTERS The PR-4Zi has seven IR outputs: Source 1–6 and Common. Source 1–6 outputs are source-specific and provide IR signals only to the selected source; the Common out- put provides IR signals to all sources. Source-specific IR outputs (Figure...
1. Turn on the PR-4Zi using its front-panel switch. 2. On the PRC-1, press the AUX and MUTE buttons simultaneously, then release. 3. Point the PRC-1 toward the PR-4Zi and press the three-digit code 0-8-1. 4. On the PRC-1, press the AUX button again to store the code.
Source Loop outputs of the parent controller to the A/V inputs of controller #2, and so on.) Figure 20 – Interface cable connections for multiple PR-4Zi’s Multiple Controllers The DB-25 cable needs to be a straight pass- through or RS232C rated with a male connector at both ends.
Page 20
Controller #4 (Zones 13-16) RS-232 COMMAND PROTOCOLS Commands are sent from RS-232 controlling device to the PR-4Zi as 8 ASCII bytes. The first two ASCII bytes “RU” establish that the command is a Russound command for zone commands only. The next 3 bytes “Z01”...
MULTI-ZONE COMMANDS RUALZOZN system on RUALZOZF system off RUSORCLC party mode (source link) RUSORCLN party mode (source/volume link) ZONE COMMANDS Zone number (XX) can be between 01 and 16. Use the addressing switch (Figure 19) to set zone numbers (01-04), (05-08), (09-12), (13-16) RUZXXZON zone on RUZXXZOF...
Dimensions: 19" W x 12" D x 3.6" H. Weight: 12 lbs. The PR-4Zi complies with the requirements of the standards for Audio Video Products and Accessories (UL 1492, 1st Edition) and Radio, Television, and Electronic Apparatus (CSA C22.2 No.
To return for repairs, the unit must be shipped to Russound at the owner’s expense, along with a note explaining the nature of the service required. Be sure to pack the unit in a corrugated container with at least 3 inches of resilient material to pro- tect the unit from damage in transit.