Siemens RUGGEDCOM RX1501 Installation Manual page 34

Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

Chapter 3
Modules
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty and open
ports are protected with plugs or covers.
Removing a Module
To remove a line module, do the following:
1.
Make sure power to the device has been disconnected and wait approximately two minutes for any remaining
energy to dissipate.
2.
[Optional] If the device is installed in a rack, remove it from the rack.
3.
Loosen the screws that secure the module.
4.
Pull the module from the chassis to disconnect it.
1
2
3
Figure 15: Removing a Module
1. Module    2. Chassis    3. Screw
5.
Install a new module or a blank module (to prevent the ingress of dust and dirt).
6.
[Optional] If necessary, install the device in the rack.
7.
Connect power to the device.
Installing a Module
To install a line module, do the following:
1.
Make sure power to the device has been disconnected and wait approximately two minutes for any remaining
energy to dissipate.
2.
[Optional] If the device is installed in a rack, remove it from the rack.
3.
Remove the current module from the slot.
4.
Insert the new module into the slot.
26
RUGGEDCOM RX1501
Installation Guide
Installing/Removing Line Modules