Power Failure Connections - Kx-Tda100/Kx-Tda200; 2.12.1 Power Failure Connections - Panasonic KX-TDA30 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA30:
Table of Contents

Advertisement

2.12 Power Failure Connections — KX-TDA100/KX-TDA200
2.12 Power Failure Connections — KX-TDA100/
KX-TDA200

2.12.1 Power Failure Connections

When the power supply to the Hybrid IP-PBX fails, power failure transfer (PFT) will switch from
the current connection to the Power Failure Connection. Refer to "2.4.1 Power Failure Transfer"
in the Feature Guide for further information.
Power Failure Connection is required to implement this feature.
Note
While DC power is provided by the backup batteries, the Hybrid IP-PBX will remain fully
operational and the connection will not switch to the Power Failure Connection.
Using Analogue Trunk Card and Extension Card
Power Failure Connection connects a specific SLT and a trunk in the event of power failure. The
following analogue trunk and extension cards can be used for Power Failure Connections:
Analogue trunk cards: LCOT16 (4 PFT ports), LCOT8 (2 PFT port), and LCOT4 (2
PFT port)
Extension cards: MSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT port)
and SLC8 (2 PFT port)
To 1 analogue trunk card, connect only 1 extension card.
Note
By programming the Hybrid IP-PBX, a trunk conversation established during power failure
can be maintained even when the power returns and the connection is switched back to
the normal configuration from the Power Failure Connection. However, if no special
programming is performed, the connection will be dropped when power returns.
Trunk Card
(e.g., LCOT8)
196
Installation Manual
RJ11
R2
R1
T1
T2
To trunk
T2
T1
R1
R2
Extension Card
(e.g., SLC8)
To SLT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda200Kx-tda100