Download Print this page
Steca PA RC100 User Manual

Steca PA RC100 User Manual

Advertisement

Quick Links

Controller PA RC100
Load disconnect LVD
Load reconnect LVR
Charge controller standard setting
Bat
Switch 1 OFF
SOC
Switch 2-ON / 3-OFF
Rotary switch 8
Night light
Float charging
13,9 (27,8) V - Rotary switch 4 13,9 (27,8) V - Rotary switch 4
Boost charging
14,4 (28,8) V - Rotary switch 4 14,4 (28,8) V - Rotary switch 4
Equal charging
14,7 (29,4) V - Rotary switch 3 14,7 (29,4) V - Rotary switch 3
Load disconnect
11,6 (23,2) V - Rotary switch 5 11,6 (23,2) V - Rotary switch 5
LVD
Load reconnect
12,4 (24,8) V - Rotary switch 5 12,4 (24,8) V - Rotary switch 5
LVR
Rotary
Night Light
Float charging
switch
0
Off
13,5 (27,0) V
1
1 h
13,6 (27,2) V
2
2 h
13,7 (27,4) V
3
3 h
13,8 (27,6) V
4
4 h
13,9 (27,8) V
5
5 h
14,0 (28,0) V
6
6 h
14,1 (28,2) V
7
7 h
14,2 (28,4) V
8
8 h
14,3 (28,6) V
9
ON
14,4 (28,8) V
Equal charging
PRS 1515
Switch 2-ON / 3-ON
Rotary switch 8
Boost
charging
14,0 (28,0) V
14,1 (28,2) V
14,2 (28,4) V
14,3 (28,6) V
14,4 (28,8) V
14,5 (29,0) V
14,6 (29,2) V
14,7 (29,4) V
14,8 (29,6) V
14,9 (29,8) V
Function
Switch 1-4
Rotary-Switch
Night light
Float charging
Boost charging
Solsum 6.6F
Switch 1 OFF
Equal
Load reconnect
charging
14,4 (28,8) V
11,5 (23,0) V
14,5 (29,0) V
11,7 (23,4) V
14,6 (29,2) V
11,9 (23,8) V
14,7 (29,4) V
12,1 (24,2) V
14,8 (29,6) V
12,3 (24,6) V
14,9 (29,8) V
12,4 (24,8) V
15,0 (30,0) V
12,5 (25,0) V
15,1 (30,2) V
12,6 (25,2) V
15,2 (30,4) V
12,8 (25,6) V
15,3 (30,6) V
12,9 (25,8) V
9 0
1
2
8
3
7
4
6
5
Function Switch 1-4
Switch 1
Battery condition
On
Liquid
OFF
Gel
Switch 2-3
SOC-Factor
OFF + OFF
0 - OFF
OFF + ON
3 - 8 mV/A
ON+OFF
4 - 16 mV/A
ON + ON
5 - 32 mV/A
Switch 4
//
ON
//
//
OFF
Load disconnect
LVR
LVD
10,8 (21,6) V
11,0 (22,0) V
11,2 (22,4) V
11,4 (22,8) V
11,5 (23,0) V
11,6 (23,2) V
11,7 (23,4) V
11,9 (23,8) V
12,1 (24,2) V
12,3 (24,6) V
User's manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the PA RC100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Steca PA RC100

  • Page 1 Controller PA RC100 Function Switch 1-4 Rotary-Switch Night light Equal charging Float charging Load disconnect LVD Boost charging Load reconnect LVR Function Switch 1-4 Charge controller standard setting Switch 1 Battery condition PRS 1515 Solsum 6.6F Liquid Switch 1 OFF...
  • Page 2 Connect a battery to supply the controller and carry out steps 3.2 and 3.3 within one minute. Place the LED of the Steca PA RC100 remote control in the recess for the green battery LED on the right. User's manual...
  • Page 3 The charge controller INFO LED flashes red = Transmission error. In this case you should separate the controller from the battery and repeat the procedure from step 3.1 or, if required, recheck the settings for the Steca PA RC100 remote control in accordance with step 2.1. Note about the night light function.