Medium Room 120V Portable Air Conditioner with 11000 BTU Heater CAUTION: READ ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE SERVICING THE UNIT EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754 support.edgestar.com • service@edgestar.com • edgestar.com *Warranty service should be performed by an authorized service representative only.
SAFETY PRECAUTIONS WARNING: This manual and the information contained herein is intended for use by certified technicians. The manufacturer or seller is not responsible for the interpretation or misuse of the information provided, nor does it assume any liability in connection with its use. The safeguards and warnings indicated in this manual do not cover all possible conditions which may occur.
Electrical Safety Do not exceed the power outlet ratings. It is recommended that the unit be connected to its own circuit. A standard electrical supply that is properly grounded in accordance with the National Electrical Code and all state and local codes and ordinances is required. ...
General Safety Always unplug an appliance from the power supply before attempting any service. Disconnect the power cord by grasping the plug, not the cord. Do not allow children or pets to play on or in the appliance. ...
1 Specifications Model AP13500G AP13500HG Rated Voltage Rated Frequency Hz Power Phases Supply Cooling Capacity Btu/h 13500 13500 Heating Capacity Btu/h 11000 Cooling Power Input 1465 1465 Heating Power Input 1250 Cooling Power Current 11.5 11.5 Heating Power Current 10.5...
Page 7
Model AP13500G AP13500HG Compressor Model QXA-B117xA030 QXA-B117xA030 Compressor Oil RB68EP/EQUIVALENT RB68EP/EQUIVALENT Compressor Type Rotary Rotary L.R.A. 54.00 54.00 Compressor RLA A 10.50 10.50 Compressor 1152 1152 Power Input Overload Protector UP3-49 UP3-49 Compress Fan Type Centrifugal Centrifugal Φ7 2/5X4 1/4 Φ7 2/5X4 1/4...
Page 9
Part Name Part Name Top Cover Assembly Water Level Switch Base Membrane Inching Switch Coping Water Level Switch Sub-assembly Display Box Supporting Board 1 Display Cover Diversion Circle Display Board Centrifugal Fan Foam (Baffle) Condenser Assembly Baffle Plate Temperature Sensor Propeller Housing 2 (Upper) Capillary Sub-assembly Swing Lever...
6.5 Auto mode Under auto mode standard cooling Tpreset=77ºF(25ºC); standard heating Tpreset=68ºF(20ºC) 6.5.1 AP13500G When Tambient > 79ºF(26ºC) the unit runs in cooling mode. When Tambient < 68ºF(20ºC) the unit runs in fan mode. If the unit is operating in fan mode and 68ºF(20ºC) ≥ Tambient ≥ 73ºF(23ºC), the unit will stay in fan...
6.5.2 AP13500HG When Tambient > 79ºF(26ºC) the unit runs in cooling mode. When Tambient < 68ºF(20ºC) the unit runs in heating mode. If the unit is operating in heating mode and 73ºF(23ºC) ≥ Tambient ≥ 68ºF(20ºC), the unit will stay in heating mode.
7 Troubleshooting 7.1 Troubleshooting Guide Problem Possible Cause Solution Wall plug is disconnected. Insert plug firmly into proper wall outlet. House fuse blown or circuit breaker Replace fuse with time delay type or reset circuit tripped. breaker. Press the RESET button on the power cord. If Power cord is tripped.
Check wire connections. Repair or tighten any Wire connections faulty. Fan louvers do not broken or loose connections. swing. Fan swing motor damaged. Replace motor. When unit is turned on or off the outer Normal sound. Outer shell is contracting or shell “pops”...
Page 18
Low refrigerant Find leak and repair. charge due to leak Recharge refrigerant. or defect. The coils are dirty or the air inlet or outlet is blocked. Clean coils and/or move/remove obstructions. Fan is not running or set too low. Increase fan speed or replace fan if defective.
Page 19
Fan is not running or set too low. Increase fan speed or replace fan if defective. Compressor is defective. Replace compressor. Restriction in refrigeration system. Locate and clear restriction, then recharge refrigerant. Ambient temperature is extreme.
Page 28
DATE REVISION NOTES 04/11/2018 INITIAL DOCUMENT EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754 support.edgestar.com • service@edgestar.com • edgestar.com *Warranty service should be performed by an authorized service representative only.
Need help?
Do you have a question about the AP13500G and is the answer not in the manual?