Edge-Core AS4610-30T Quick Start Manual

Edge-Core AS4610-30T Quick Start Manual

24/48-port ge top-of-rack switch
Hide thumbs Also See for AS4610-30T:

Advertisement

Quick Links

Quick Star t Guide
24/48-Port GE Top-of-Rack Switch
AS4610-30T / AS4610-30P / AS4610-54T / AS4610-54P
1. Unpack the Switch and Check Contents
Rack Mounting Kit—two brackets and eight screws
Four adhesive foot pads
Power Cord—either Japan, US, Continental Europe
or UK
Console Cable—RJ-45 to DB-9
Micro-USB to RJ-45 Jack Cable
Documentation—Quick Start Guide (this document)
and Safety and Regulatory Information
Note:
For information on switch software, refer to
www.edge-core.com.
Switches with part numbers 4610-30/54-D*-******** have
switch software pre-loaded on the switch. Software user
documentation can be found at www.edge-core.com.
Switches with part numbers 4610-30/54-O-******** have
the Open Network Installer Environment software installer
pre-loaded on the switch, but no switch software image.
Information about compatible switch software can be
found at www.edge-core.com.
Warning:
For indoor use only. The switch, AC power, and
all connected cables are not designed for outdoor use.

2. Mount the Switch

2
1
Attach the brackets to the switch.
www.edge-core.com
AS4610-30T
AS4610-30P
AS4610-54T
AS4610-54P
1
– 1 –
2
Use the screws and cage nuts supplied with the rack to
secure the switch in the rack.
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack,
while the other secures it using the rack screws.
Note:
The switch can also be installed on a desktop or shelf
using the included adhesive rubber foot pads.
3. Ground the Switch
2
1
1
Ensure the rack on which the switch is to be mounted is
properly grounded and in compliance with ETSI ETS 300 253.
Verify that there is a good electrical connection to the
grounding point on the rack (no paint or isolating surface
treatment).
2
For a PoE switch, attach a lug (not provided with PSU) to a
#12 AWG minimum grounding wire (not provided with PSU),
and connect it to the grounding point on the switch rear
panel. Then connect the other end of the wire to rack
ground.
For a Non-PoE switch, attach a lug (not provided with PSU) to
a #18 AWG minimum grounding wire (not provided with
PSU), and connect it to the grounding point on the switch
rear panel. Then connect the other end of the wire to rack
ground.
Caution:
The earth connection must not be removed
unless all supply connections have been disconnected.

4. Connect Power

1
2
1
Install one or two universal AC power modules in the switch.
2
Connect an external AC power source to the modules.
E062015-AP-R01
150200001150A

Advertisement

loading
Need help?

Need help?

Do you have a question about the AS4610-30T and is the answer not in the manual?

Questions and answers

Summary of Contents for Edge-Core AS4610-30T

  • Page 1: Connect Power

    Quick Star t Guide 24/48-Port GE Top-of-Rack Switch AS4610-30T / AS4610-30P / AS4610-54T / AS4610-54P Use the screws and cage nuts supplied with the rack to 1. Unpack the Switch and Check Contents secure the switch in the rack. Caution:...
  • Page 2: Verify Switch Operation

    PSU1/PSU2, System and FAN LEDs should all be on green. For RJ-45 ports, connect 100-ohm Category 5, 5e or better twisted-pair cable. For AS4610-30T/AS4610-54T, when operating normally, the PSU1/PSU2 and System LEDs should all be on green. For AS4610-30P, ports 1-16 can suport PoE connections up to 30 W and ports 17-24 can support UPoE connections up to 60 W.
  • Page 3: Hardware Specifications

    Plug one end of a 40GBASE-CR4 DAC cable in the bottom Humidity Operating: 5% to 95% (non-condensing) QSFP+ port of the top unit. 150 W AC PSU (AS4610-30T/ AS4610-54T) Plug the other end of the DAC cable into the top QSFP+ port AC Input 100-240 VAC, 50-60 Hz, 3-1.5 A of the next unit.