ISSUE 1.0
Program 80 : Basic Hardware Setup for System
Level
IN
Description
Use Program 80-11 : MFC Tone Receiver Setup to various data for the MFC signal detection.
Input Data
Item No.
Item
01
02
03
04
05
06
Programming Manual
Downloaded from
www.Manualslib.com
MFC Tone Receiver Type Number
Item
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Twist level
06
S/N ratio
07
ON detect time
08
OFF detect time
Name
Type 1
Detect Level
0
Start delay time
0
Min. detect level
15 (- 25 dBm)
Max. detect level
0 (0 dBm)
Twist level
9 (10 dBm)
S/N ratio
2 (0 dBm)
manuals search engine
80-11 : MFC Tone Receiver Setup
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (0.25 step, 0 ms ~ 64 ms)
0 ~ 15
detect level 0 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 1 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 2 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 3 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 4 = - 30 dBm (0) ~ - 45 dBm (15)
detect level 5 = - 35 dBm (0) ~ - 50 dBm (15)
detect level 6 = - 40 dBm (0) ~ - 55 dBm (15)
0 ~ 15
detect level 0 = 0 dBm (0) ~ - 15 dBm (15)
detect level 1 = - 5 dBm (0) ~ - 20 dBm (15)
detect level 2 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 3 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 4 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 5 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 6 = - 30 dBm (0) ~ - 45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
0 ~ 4 (- 5 step, 0 dB ~ - 20 dB)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
Table 2-17 Default Table
Type 2
Type 3
0
0
0
0
15 (- 25 dBm)
15 (- 25 dBm)
0 (0 dBm)
0 (0 dBm)
9 (10 dBm)
9 (10 dBm)
2 (0 dBm)
2 (0 dBm)
SL1000/SL1100
1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
3 = Reserved
4 = Reserved
5 = Reserved
Input Data
Type 4
Type 5
0
0
15 (- 25 dBm)
15 (- 25 dBm)
0 (0 dBm)
0 (0 dBm)
9 (10 dBm)
9 (10 dBm)
2 (0 dBm)
2 (0 dBm)
Program
80
0
0
2-435