The wire which is coloured green and yellow must be connected to the terminal
in the connection unit which is marked with the letter E or by the earth
symbol:
The wire which is coloured blue must be connected to the terminal which is
marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
4.21 Wiring Diagrams:
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
BLUE
FLOWSWITCH
BROWN
REED (S2)
S2 S2
S1
Single Pumps
Fig. 13
4.22 Fuses: The following fuse size should be used with the appropriate pump.
Model
All Models
4.23 Supply Cord Replacement:
If the supply cord is to be changed or is damaged, it must be replaced with a
special cord assembly available from Stuart Turner or one of their approved
repairers.
On disassembly note the cord retention and routing system. Re-assemble to the
same pattern.
For information on cable connection consult the wiring diagram and cable gland
fitting instructions.
or coloured green or green and yellow.
N
L
LOAD
S1
GREEN / YELLOW
BROWN
BLUE
Fuse Size (AMPS)
The supply cord and internal wiring within the terminal
box are routed and secured to ensure compliance with the
electrical standard EN 60335-1. It is essential that prior to
any disturbance of this internal wiring, all cable routing and
securing details are carefully noted to ensure re-assembly to
the same factory pattern is always maintained.
CAPACITOR
BLUE
FLOWSWITCH
BROWN
REED (S2)
FLOWSWITCH
REED (S1)
E
230 VAC/1PH/50Hz
L
SUPPLY
N
5
- 14 -
MAIN WINDING
THERMOTRIP
START WINDING
S2 S2
N
L
LOAD
S1
S1
BLUE
BROWN
Twin Pumps
Fig. 14
GREEN / YELLOW
E
BROWN
230 VAC/1PH/50Hz
L
BLUE
SUPPLY
N
Cont ...