Keep clear of steps as they are deployed. Step actuation takes approximately two seconds whether extending or retracting.
Keep hands and fingers away from step mechanism during actuation process to prevent serious bodily injury.
TEST PROCEDURE PRIOR TO INSTALLATION
1. Steps will install easier when extended first. Place steps upside down on workbench or floor.
2. Cut and connect four (4) jumper wires to the 4-pin connector. Match the jumper wires to the posts on the connector color for color.
3. Connect GREEN WIRE to the NEGATIVE post of a fully charged, 12V automotive battery.
4. Connect RED and WHITE WIRES to the POSITIVE post of the battery.
5. Connect the BROWN WIRE to the NEGATIVE post of the battery.
6. Disconnect jumper wires from the battery.
Steps must be installed using four (4) 5/16", GR 8 bolts, lock washer and nuts for the Automatic Elctric Steps and 3/8" bolts, lock washers and
nuts for the Automatic Electric Slideing Step. Retract steps by attaching wires in the following sequence:
1. Ground the GREEN WIRE to the chassis.
2. Touch the RED and WHITE wires to the positive terminal on the battery.
Proceed to install door switch and power switch(items not included). The wires of the four pin connector must be routed as follows:
1. WHITE - Connect to power switch (16 ga. min. wire).
2. YELLOW - Must be connected to power source that is only hot when ignition is "ON." Protect with 6A fuse or breaker (16 ga. min. wire).
3. RED - Connec to power for motor. Protect with 25A fuse (10 ga. min. wire).
4. BROWN - Connect to door switch (16 ga. min. wire).
C
OACH
I
, O
NSTALLATION
PERATION AND
E
S
LECTRIC
TEPS AND
R
FOR
ECREATIONAL

INSTALLATION PREP

WARNING!
WARNING!
Steps will extend immediately!

INSTALLATION

WARNING!
Keep clear of the steps as they will retract quickly.
3
Fig. 1
S
TEP
S
M
ERVICE
ANUAL
A
E
UTOMATIC
LECTRIC
V
EHICLES
2
1
S
S
LIDING
TEPS
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COACH STEP and is the answer not in the manual?

Questions and answers

Summary of Contents for Lippert Components COACH STEP

  • Page 1 LIPPERTCOMPONENTS, INC. OACH NSTALLATION PERATION AND ERVICE ANUAL UTOMATIC LECTRIC TEPS AND UTOMATIC LECTRIC LIDING TEPS ECREATIONAL EHICLES INSTALLATION PREP WARNING! Keep clear of steps as they are deployed. Step actuation takes approximately two seconds whether extending or retracting. Keep hands and fingers away from step mechanism during actuation process to prevent serious bodily injury. TEST PROCEDURE PRIOR TO INSTALLATION 1.
  • Page 2 INSTALLATION - DOOR SWITCH Lippert Components, Inc. (LCI) recommends the use of the LCI supplied switch. However, if another switch is to be used, it must be a switch held open in the presence of a magnet and should have a triggering distance of no more than one inch.
  • Page 3 WARNING! With Power Switch “ON,” door open and steps extended, it is possible to drive off. Damage to steps or vehicle is possible, as well as serious personal bodily injury or death. STEP OPERATION - POWER “OFF” 1. With door open, steps extended and Power Switch turned “OFF,” steps remain extended; amber light shuts off. 2.
  • Page 4 SERVICE NOTES A. Use locktite on any bolts removed and replaced. NOTE: It is recommended that if the nut is removed and replaced in the field, a liquid “Loctite” locking compound be applied before tightening. The joint shoulder bolts should be torqued to a minimum of 140 inch pounds. B.