Item
Condition
Panel tuning
mode
9. P25
1) Adj item:
H-CPM
[P2 P2DEV]
Devia-
Adjust:[****]
tion ad-
2) Adj item:
just
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA High]→
[TX Low]→
[TX High]
[Frequency:
800MHz Band]
[TX Low]→
[TX High]→
[RX/TA Low]→
[RX/TA High]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
10.
1) Adj item:
NXDN
[Nn NDEV]
High
Adjust:[****]
Devia-
2) Adj item:
tion ad-
[Frequency:
just
700MHz Band]
[NXDN
[RX/TA Low]→
Narrow]
[RX/TA High]→
[TX Low]→
[TX High]
[Frequency:
800MHz Band]
[TX Low]→
[TX High]→
[RX/TA Low]→
[RX/TA High]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
1-48 (No.RA016<Rev.001>)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Devia-
[P25 H-CPM Devi-
tion
ation]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA High]→
[TX Low]→
[TX High]
[Frequency:
800MHz Band]
[TX Low]→
[TX High]→
[RX/TA Low]→
[RX/TA High]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[NXDN High Devia-
tion
tion (NXDN Nar-
meter
row)]
Oscil-
Deviation meter
lo-
LPF: 3kHz
scope
HPF: OFF
2) Adj item:
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA High]→
[TX Low]→
[TX High]
[Frequency:
800MHz Band]
[TX Low]→
[TX High]→
[RX/TA Low]→
[RX/TA High]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Adjustment
Method
Write fixed value "485"
3090~3215Hz
for each adjustment
point. Transmit at each
[PC test
adjustment point and
mode]
check that the deviation
Press [Apply
is between 3090Hz and
All] button to
3215Hz.
store the
Deviation meter
adjustment
LPF: 3kHz
value after all
HPF: OFF
adjustment
points have
[Panel tuning mode]
been adjusted.
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write fixed value "505"
2995~3117Hz
for each adjustment
point. Transmit at each
[PC test
adjustment point and
mode]
check that the deviation
Press [Apply
is between 2995Hz and
All] button to
3117Hz.
store the
Deviation meter
adjustment
LPF: 3kHz
value after all
HPF: OFF
adjustment
points have
[Panel tuning mode]
been adjusted.
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button