Item
Panel test
mode
5-1.
1)CH-Sig: 2-1
Sensitivity
SSG output
check
Wide 5k:
[700M
-117dBm
band]
(0.32µV)
(MOD:
1kHz/±3kHz)
Wide 4k:
-117dBm
(0.32µV)
(MOD:
1kHz/
±2.4kHz)
Narrow:
-117dBm
(0.32µV)
(MOD: 1kHz/
±1.5kHz)
5-2.
1)CH-Sig: 8-1
Sensitivity
SSG output
check
Wide 5k:
[800M
-117dBm
band]
(0.32µV)
(MOD:
1kHz/±3kHz)
Wide 4k:
-117dBm
(0.32µV)
(MOD:
1kHz/
±2.4kHz)
Narrow:
-117dBm
(0.32µV)
(MOD: 1kHz/
±1.5kHz)
4.8
Common Section
Item
Condition
Panel tuning
mode
1.
1) BATT terminal voltage:7.5V
Setting
2) SSG standard modulation
[Wide 5k] MOD:1kHz,DEV:3kHz
[Wide 4k] MOD:1kHz,DEV:2.4kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
Condition
PC test mode
1)Test Channel
Channel: 2
Test Signaling Mode: Analog
Signaling: 1
SSG output
Wide 5k: -117dBm (0.32µV)
(MOD: 1kHz/±3kHz)
Wide 4k: -117dBm (0.32µV)
(MOD: 1kHz/±2.4kHz)
Narrow: -117dBm (0.32µV)
(MOD: 1kHz/±1.5kHz)
1)Test Channel
Channel: 8
Test Signaling Mode: Analog
Signaling: 1
SSG output
Wide 5k: -117dBm (0.32µV)
(MOD: 1kHz/±3kHz)
Wide 4k: -117dBm (0.32µV)
(MOD: 1kHz/±2.4kHz)
Narrow: -117dBm (0.32µV)
(MOD: 1kHz/±1.5kHz)
Measurement
PC test mode
Test-
equip-
ment
Measurement
Test-
Unit Terminal Unit Parts
equipment
SSG
Panel ANT
AF VTVM
Universal
Oscilloscope
connector
Distortion
meter
8Ω Dummy
load
SSG
Panel ANT
AF VTVM
Universal
Oscilloscope
connector
Distortion
meter
8Ω Dummy
load
Adjustment
Unit
Ter-
Unit
Parts
minal
Adjustment
Specifica-
tions
Method
/Remarks
Check
12dB SINAD
or more
Check
12dB SINAD
or more
Specifications
/Remarks
Method
(No.RA016<Rev.001>)1-41