Page 1
Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS...
Standard Master User Functions __________________________________________________________________________ 75 Setting the Time and Date _______________________________________________________________________________ 83 Master Mode menu _____________________________________________________________________________________ 83 Alarm Memory _________________________________________________________________________________________ 84 New Partition Menu on LCD keypads ______________________________________________________________________ 85 Trouble conditions ______________________________________________________________________________________ 86 Quick Guide ___________________________________________________________________________________________ 87 IDS X Series Training V2.3 | Contents...
Example: If zones above 16 are mentioned then X64 is being described. Training must be done with X64 panels as some of the exercises are not suitable for X16. Features | IDS X Series Training V2.3...
Panel Status LED The status LED indicates the condition of the operating system. 4. Serial Output The serial output is for connecting the voice module, serial communicators and direct download device. Ground Serial Connector IDS X Series Training V2.3 | Hardware...
Page 6
The Tx connection can supply enough power for radios up to 15 watts. NOTE: Please use cable with a minimum of 0.5mm copper core depending on the distance between system and radio transmitter. Hardware | IDS X Series Training V2.3...
Page 7
NOTE: The end of line resistor must be 3K3Ω (Ω = ohm) For a tamper installation a 12kΩ and a 4K7Ω End of Line 3k3 Ohm 12K & a 4k7 Ohm resistor resistor IDS X Series Training V2.3 | Hardware...
Note: To learn the dual PIR to the X- first get both PIR heads to detect movement then press Series the tamper switch when in location 260 sub-location 1 and the correct zone number has been selected Wireless Device Hardware setup | IDS X Series Training V2.3...
Page 9
X-Series alarm Note: To learn the door contact to the X-Series press the tamper switch when in location 260 sub- location 1 and the correct zone number has been selected. IDS X Series Training V2.3 | Wireless Device Hardware setup...
Thousands Units Zone Value Zone Value 1000 2000 4000 8000 Hundreds Tens Zone Value Zone Value Example: Zone Value Zone Value Total Total The value is 124 The value is 9 Entering Data | IDS X Series Training V2.3...
Clear any previously pressed keys that maybe in memory Enter the installer code and confirm with a * (Default is 9999) [9] [9] [9] [9] [*] The ready LED will begin to flash indicating installer mode IDS X Series Training V2.3 | Programming...
When the [*] key is pressed at the end of the string, you will be removed out of the location and the data saved. If there is an error you will hear 3 error beeps, and will remain in the location to re-enter the data. Programming | IDS X Series Training V2.3...
Page 13
[Location Number] [*] [Value] [*] Bitmap Location [Location Number] [*] [Option] [*] [Option] [*]..[#] Sub-location method [Location Number] [*] [Sub-location Number] [*] [Value] [*] String method [Location number] [*] [all values to be entered] [*] IDS X Series Training V2.3 | Programming...
Page 14
[0] [*] The keypad will begin to beep until all locations have been reset. The LEDs on the keypads will flash indicating that they have no IDs and the system is defaulted. Location 1 to 8: Zone Type Location Type:...
When the panel is armed the violation of an Outdoor Instant zone will cause the panel OUTDOOR to register an alarm condition the only difference compared to instant zone is the INSTANT ZONE contact ID code sent to the control room. Exercise: IDS X Series Training V2.3 | Locations...
Location 11: Programmable Zone Loop Response Time Location Type: Standard This is the time that the zone must be violated before the zone will register a violation. Valid Range: 1 - 255 Default: 2 Global Settings | IDS X Series Training V2.3...
Page 17
This is the number of times the zone must violate within the time set in location 12, Cross-zone delay time, above. Valid Range: 1 -15 Default: 3 Note: Each zone must be enabled to be part of the cross-zone group. (Location 101 to 164 depending on the zone number) IDS X Series Training V2.3 | Global Settings...
Page 18
This is the time the system waits before reporting that the electricity has been disconnected. Data format: hhmm Valid Range: 0001 - 1800 Default: 0004 Note: AC restoral waits for one minute before reporting the restoral. Global Settings | IDS X Series Training V2.3...
Page 19
RSSI is signal strength measurement and if lower than 20% a Wireless low RSSI trouble will be logged If a zone is monitored for tamper and then a tamper signal is Zone tamper detected by the alarm a trouble will be triggered. IDS X Series Training V2.3 | Global Settings...
Page 20
Location 21: Keypad Lockout Time Location Type: Standard This is the time the keypad will not respond to any key presses except for the panic button. Data format: mmss Valid Range: 0001 - 5959 Default: 0030 Global Settings | IDS X Series Training V2.3...
March August December April Location 26: Day of the Week to Start Daylight Savings Location Type: Standard Select the day that daylight savings begins Value Monday Tuesday Wednesday Thursday Friday Saturday Sunday IDS X Series Training V2.3 | Daylight Savings...
Page 22
Location 31: Daylight Savings Time Offset Location Type: Standard This is the value that the time must be offset by when daylight savings is enabled. Data Format: mmm Valid Range: 1 - 250 Default: 060 Advanced Miscellaneous Settings | IDS X Series Training V2.3...
This is the time the alarm will wait before reporting an event; it must be enabled under partition options in locations 221 to 228. Data Format: mmss Valid Range: 0001 to 5959 Default: 0000 Communication Settings | IDS X Series Training V2.3...
Page 25
Location 48: Download Options Location Type: Bitmap The IDS X-Series alarm system can be up / downloaded with IDSwift software over a standard phone line, via an IDS modem. The following options help the system to deal with incoming calls.
Page 26
Note: If the account code is 0000 no reporting will take place. This also allows you to configure which partitions report and which do not. Communication Settings | IDS X Series Training V2.3...
Instructions Key Presses Enter location 116 [1][1][6] [*] Select the silent zone option [4] [*] LED 4 will come on Exit the location IDS X Series Training V2.3 | Zone Properties...
This is the time the panel will wait before triggering the alarm, once all movement has stopped. If movement is detected within this time, the system resets and waits for all movement to stop again. Format: HHmm Default: 0000 Valid range: 0000 to 2359 Auto Arm and Auto Alarm | IDS X Series Training V2.3...
Page 29
Time that the partition must auto arm entered in 24 hour format (HHMM H=hour, M=minute) Instructions Key presses Enter location 180 [1][8][0] [*] Enter the partition number [1] [*] Enter the time for the partition to auto arm [2] [0] [3] [0] [*] IDS X Series Training V2.3 | Auto Arm and Auto Alarm...
Enter location 197 [1][9][7] [*] Enter the new installer code [8] [4] [2] [1] [*] Note: It is important to change the installer code to minimise the risk of someone changing any settings. Security Options | IDS X Series Training V2.3...
Page 31
All no zone activity alarm settings Default: 8888 Valid range: 0001 to 9999 Instructions Key presses Enter location 197 [1][9][9] [*] Enter the new installer code [4] [3] [2] [1] [*] IDS X Series Training V2.3 | Security Options...
The diagrams below show which page is being displayed via the keypad LEDs and which zones they represent for the X64 Curve keypad LEDs Zones: 1 to 16 17 to 32 33 to 48 49 to 64 Classic keypad LEDs Partition Options | IDS X Series Training V2.3...
Page 33
Let us enable siren toot on arm and disarm so the customer will know if the alarm is armed when using a remote transmitter. Instructions Keypad presses Enter the partitions location [2][1][1] [*] Option 10 and 11 need to be enabled [1][0] [*] [1][1] [*] Exit the location IDS X Series Training V2.3 | Partition Options...
Page 34
When the entry/exit zone triggers, it automatically disables the follower zones. There is a secondary entry delay (location 232) for a different entry times. Format: mmss Default: 0030 Valid range: 5959 to 5959 Partition Options | IDS X Series Training V2.3...
[1] [2] [3] [4] [1] [1] [1] [1] [*] leave as default by leaving them in partition 1 When the [*] key is entered the data will be saved and you will be exited out of the location IDS X Series Training V2.3 | Keypad Configuration...
Page 36
You could also map the keypad zone to zone 33 even though you don‟t have an expander with zone 33 physically connected. NOTE: Please remember that you still need to give the zone a zone type and place it into a partition for it to work. Keypad Configuration | IDS X Series Training V2.3...
Page 37
Configure keypad 1, to be a global keypad with the partition menu active Instructions Key presses Enter the location for keypad 1 [2][5][1] [*] Option 3 must be enabled [3] [*] Enable partition menu [5] [*] Exit the location IDS X Series Training V2.3 | Keypad Configuration...
These error pulses will be separated by a 1sec pause with the LED off. Pulse error number: 1. Duevi receiver module not responding 2. No activity on the X-Series serial bus 3. No X-Series messages detected Wireless | IDS X Series Training V2.3...
Page 39
Note: Each time a new page of zones are shown the Pwr, Rdy, Arm and Away LEDs will change to show which zones are being displayed. Zones 1 to 16 Zones 17 to 32 Zones 33 to 49 Zones 49 to 64 Example: IDS X Series Training V2.3 | Wireless...
Page 40
Incorrect or pre-allocated serial numbers will also result in a 3 beep error tone and the menu will keep waiting for a valid entry. 3. Upon valid Serial Number entry or tamper the user will be presented with the following. Wireless | IDS X Series Training V2.3...
Page 41
2. Enter or scroll to the zone to be deleted Scroll using Medical or Panic Keys, Enter with [*] key Indicates that this zone is a wireless zone 3. Press the [*] key to select the zone IDS X Series Training V2.3 | Wireless...
Page 42
Default: 2 (24 hour) Valid range: 1 – 2 Note: All devices must be set to the correct supervision time corresponding to the selection in the supervision monitoring sub-location. Please appendix for hardware supervision settings Wireless | IDS X Series Training V2.3...
Once the installer code has been entered after an alarm has tripped a Installer reset restored restoral will be sent Box tamper On the alarm panel is a connector that a switch can be connected to IDS X Series Training V2.3 | Reporting Codes...
Page 44
Each location represents a set of 16 zones: Location 304 is zones 1-16 Location 306 is zones 33-48 Location 305 is zones 17-32 Location 307 is zones 39-64 Reporting Codes | IDS X Series Training V2.3...
Location Description Explanation Loc. 304 to 307 When the system is armed, a 24Hr zone or a panic zone is triggered 1 to 16 Zone alarm reporting this code is reported 308 to 311 1 to 16 Zone alarm restoral When the zone restores after being violated this code is sent 312 to 315 If the tamper monitoring option is enabled and a tamper signal is...
Latch is when the output will go from zero to 12 volts and stay there until something else tells it to go back to zero volts, like a light switch. Defaults: Output Event Action Panic and Duress Pulse to 12V Burglary Pulse to 12V Latch to 12V Disarm Unlatch to 0V Triggering Outputs | IDS X Series Training V2.3...
Page 47
Location 381 to 386: Clear Programmable Zone Expander Outputs on Disarm Location Type: Bitmap Any outputs enabled in this location will be reset when the alarm system is disarmed. The zone expander outputs are: Expander Output Default: OFF IDS X Series Training V2.3 | Triggering Outputs...
Page 48
If any panic event is triggered 409 Fire Programmable Output If a fire zone is triggered 410 Tamper Zone Programmable Output If a zone is set to be of the zone type tamper Triggering Outputs | IDS X Series Training V2.3...
Page 49
Download Programmable Output download software Siren Tamper Programmable Output If siren monitoring is enabled and the siren goes missing Aux 12V Trouble Programmable The 12V output on the panel is monitored constantly Output IDS X Series Training V2.3 | Triggering Outputs...
Page 50
Each of the five onboard outputs can be lengthened or shortened. [Installer Code] [*] [4] [2] [8] [*] [Output No.] [*] [m] [m] [s] [s] [*] Data format: mmss Valid Range: 0000 – 5959 Default: 0002 Configuring pulse length | IDS X Series Training V2.3...
Page 51
This location has 8 sub-locations representing Each keypad has an output that can be triggeredthe output on each keypad. [Installer Code] [*] [4] [5] [7] [*] [Output No.] [*] [h] [h] [m] [m] [*] Data format: hhmm Valid Range: 0000 – 2359 (2400 disables) Default: 2400 IDS X Series Training V2.3 | Scheduled Output triggers...
At the auto test report, the system will try and Zone swinger restore the zone if it is not violated and this shutdown restore will be reported via telephone Event Reporting Codes | IDS X Series Training V2.3...
Page 53
Wireless Detector RSSI from detectors and if the signal drops below 20% a message will be sent to alert the security company AC Restored After AC is restored a message can be sent IDS X Series Training V2.3 | Event Reporting Codes...
Page 54
Dedicated Panic if this is triggered a panic signal will be sent The alarm can be configured to send a test report Test Report every 6 hours to every 14 days Event Reporting Codes | IDS X Series Training V2.3...
Page 55
The voice module, if installed, will report programmed events to the telephone numbers entered into these locations. Depending on the location the telephone number is entered into will depend on the partition the person can interact with via the voice module. IDS X Series Training V2.3 | Event Reporting Codes...
Telephone Module 1 Open Telephone Module 2 Stay Close Telephone Module 1 Siren Cancel Telephone Module 2 Appendix 1. Extra Contact ID Zone Reporting……………………………………………………………………..57 2. Communication Default Settings.…………………………………………………………………….59 3. Features Grouped by Location……………………………………………………………………….67 Appendix | IDS X Series Training V2.3...
Loss of supervision - RF Zone Gate valve sensor Zone Loss of supervision - RPM Zone Low water level Zone Sensor tamper Zone Pump activated Zone RF low battery Zone IDS X Series Training V2.3 | Contact ID Zone Reporting...
Page 58
Reserved for Ademco Use Zone Access RTE shunt Zone Reserved for Ademco Use User Access DSM shunt Zone Reserved for Ademco Use User Access reader disable Zone System Inactivity Sounder/Relay Disable Zone Contact ID Zone Reporting | IDS X Series Training V2.3...
Location 46 Reporting Option Factory Default 5 Action Default Enable Tone Dialling Keep Two Separate Telephone Numbers Disable Dual Reporting Disable Alternate Reporting Locations 51 – 54 Primary Telephone Numbers Clears all numbers IDS X Series Training V2.3 | Default 5...
Page 60
Zone force arm reporting Telephone module 1 Zone tamper reporting Telephone module 1 Zone tamper restore reporting Telephone module 1 Zone swinger shutdown reporting Telephone module 1 Zone swinger shutdown restore Telephone module 1 reporting Default 5 | IDS X Series Training V2.3...
Page 61
Telephone module 1 Battery Restore Telephone module 1 Aux 12V Restored Telephone module 1 Installer Reset restored Telephone module 1 Box tamper restored Telephone module 1 Bus device tamper restored Telephone module 1 IDS X Series Training V2.3 | Default 5...
Page 62
Telephone module 1 Enable keypad lockout reporting Telephone module 1 Reserved Reserved Disable armed without user code Telephone module 1 reporting Reserved Reserved Location 600 – 616 Voice Module Phone Numbers All numbers cleared Default 6 | IDS X Series Training V2.3...
Location 46 Reporting Options Factory Default 6 Action Default Tone Dialling Join the Telephone Numbers Together Disable Dual Reporting Disable Alternate Reporting Locations 51 – 54 Primary Telephone Numbers Clears all numbers IDS X Series Training V2.3 | Default 6...
Page 64
Zone force arm reporting Telephone module 1 Zone tamper reporting Telephone module 1 Zone tamper restore reporting Telephone module 1 Zone swinger shutdown reporting Telephone module 1 Zone swinger shutdown restore Telephone module 1 reporting Default 6 | IDS X Series Training V2.3...
Page 65
Telephone module 1 Battery Restore Telephone module 1 Aux 12V Restored Telephone module 1 Installer Reset restored Telephone module 1 Box tamper restored Telephone module 1 Bus device tamper restored Telephone module 1 IDS X Series Training V2.3 | Default 6...
Page 66
Telephone module 1 Keypad lockout reporting Telephone module 1 Reserved Reserved Armed without user code Telephone module 1 reporting Reserved Reserved Location 600 – 616 Voice Module Phone Numbers Clears all Numbers Features Grouped by Locations | IDS X Series Training V2.3...
Training Manual Multi-Language with Wireless User Menu Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS User Menu | IDS X Series Training V2.3...
To access zones above 16 bypassed and event log press the [*] key to page to the information from the last arm next 16, until the correct page cycle. with the zone is located IDS X Series Training V2.3 | Keypad Key Descriptions...
Enter each zone to be bypassed until complete, then press the [#] [5][*][1][7][*][1][8][*][2][1][*]..[#] key to exit There are 4 stay profiles so that different zones can be bypassed depending on different scenarios that may arise. Standard User Functions | IDS X Series Training V2.3...
Page 73
Press the [5] key, then the keypad will ask you in which stay profile to arm. This feature only works with an LCD keypad. Note: This option must be enabled under installer settings, location 251 – 258: Keypad Options IDS X Series Training V2.3 | Standard User Functions...
Page 74
To access the next 16 zones press the [*] key, and add the zones as needed When complete press the [#] key The zone LED will be on Panic zones can be bypassed if enabled in zone options location 101 to 164 Standard User Functions | IDS X Series Training V2.3...
Allows for the editing of the user code properties for a selected user code. Option 11 Allows for the allocation of a selected user code to a designated partition(s). Option 13 Allows for the editing of user outputs. IDS X Series Training V2.3 | Standard Master User Functions...
Page 76
[8][7] [*] Now enter the user code to be deleted, followed by the [*] key [2][5][8][0] [*] When complete press the [#] key This will leave you in the master menu Standard Master User Functions | IDS X Series Training V2.3...
Page 77
Below is a table of all the user properties, we will make a Duress Code (followed by the [2] [*] [*] key) When complete press the [#] key This will leave you in the master menu IDS X Series Training V2.3 | Standard Master User Functions...
Page 78
The output will be set to 12V for 3 seconds then reset back to 0V Used when the output is already at 12V. This will reset the output to 0V Pulse Output Low and restore it to 12V after 3 seconds Standard Master User Functions | IDS X Series Training V2.3...
Page 79
Button 1 = Arm / Disarm Button 3 = Stay Arm Any button held down for more than three seconds will cause a panic to trigger Stay Arm Arm / Disarm IDS X Series Training V2.3 | Standard Master User Functions...
Page 80
Enter the remote receiver ID that the transmitter is to be taught to, followed by the [*] key [1] [*] Now enter the user code, followed by the [*] key [2][4][6][8] [*] When complete press the [#] key This will leave you in the remote receiver menu Standard Master User Functions | IDS X Series Training V2.3...
Page 81
[1] [*] Enter the pulse time in mmss, followed by the [*] key [0][0][1][0] [*] When complete press the [#] key This will leave you in the remote receiver menu IDS X Series Training V2.3 | Standard Master User Functions...
Page 82
Enter the value to select a language, followed by the [*] key [3][1] [*] Scroll to the language, followed by the [*] key to select [Panic] [*] When complete press the [#] key Standard Master User Functions | IDS X Series Training V2.3...
Toggle onboard outputs Toggle between LCD alphanumeric display and LED simulation display Note: As before the first key press must be held until a beep is heard. (Approx. 3 seconds) IDS X Series Training V2.3 | Setting the Time and Date...
Zones that were bypassed Any zones that were bypassed for that arm cycle All zones that were fiddled with and their tamper Press [3][*] Tampered zones monitoring circuits triggered Press [6] [*] Event log Alarm Memory | IDS X Series Training V2.3...
S = stay armed v. A = away armed LCD Screen vi. ! = alarm Note: This option must be enabled under installer settings, location 251 – 258: Keypad Options IDS X Series Training V2.3 | New Partition Menu on LCD keypads...
Zone tamper alarm a trouble will be triggered. Once the trouble has been corrected, press and hold [7] again, and [#] immediately thereafter. AC failure will clear automatically, once AC has been restored. Trouble conditions | IDS X Series Training V2.3...