Sel 651RA Installation Instructions Manual
Sel 651RA Installation Instructions Manual

Sel 651RA Installation Instructions Manual

8-pin (size 22) receptacle for voltage inputs

Advertisement

Introduction
Parts
Installation
Date Code 20160329
SEL-651RA Installation Instructions for 8-Pin
(Size 22) Receptacle for Voltage Inputs
This 8-pin (size 22) receptacle provides an eight-pin male receptacle that exits
from the bottom of the cabinet. The 8-pin cable is internally wired to 300 Vac
voltage max inputs. The 8-pin receptacle provides a convenient way (by way
of external cable, which is not included) to connect external potential
transformer secondary outputs to the control. Depending on the secondary
input voltage option of your control, you may wire to just the Y-side, just the
Z-side, or both Y- and Z-side voltage inputs.
SEL Part Number
SEL-C2253
SEL-C5241
080-0101
140-0500
140-0740
144-0140
310-0050
Step 1. Install the 8-pin (size 22) voltage input receptacle harness in
the bottom of the cabinet in the center hole in the back row. See
Figure 1.
Step 2. Install the smaller ring terminal of the green/yellow ground
wire and the two drain wires to the last connector screw and
secure them with the last nut. See Figure 1.
Step 3. Use the existing nut to connect the larger ring terminal of the
green/yellow ground wire to the ground stud. See Figure 1.
Description
8-pin (size 22) voltage input receptacle harness
Ground wire
5/8 steel wire clamp
4-40 x 1/2" screw
4-40 hex nut
Plastic cap
Zip ties
a. Insert the receptacle harness inside the cabinet and
insert the four screws from outside.
b. Install the nuts on the screws from the inside of the
cabinet.
Quantity
1
1
2
4
4
1
12
SEL-651RA Recloser Control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 651RA and is the answer not in the manual?

Questions and answers

Summary of Contents for Sel 651RA

  • Page 1 SEL-651RA Installation Instructions for 8-Pin (Size 22) Receptacle for Voltage Inputs Introduction This 8-pin (size 22) receptacle provides an eight-pin male receptacle that exits from the bottom of the cabinet. The 8-pin cable is internally wired to 300 Vac voltage max inputs. The 8-pin receptacle provides a convenient way (by way of external cable, which is not included) to connect external potential transformer secondary outputs to the control.
  • Page 2: Wiring Without Fuse Block

    Step 4. Use the existing nuts to secure the wires to the top of the control module with the two accessory wire clamps (if they are not already installed). See Figure 3. SEL-651RA Recloser Control Date Code 20160329...
  • Page 3 B (Brown Wire) C (Red Wire) D (Orange Wire) E (Black Wire) F (Brown Wire) G (Red Wire) H (Orange Wire) Figure 4 Attach Wires to Control Module Step 6. Zip tie wires as necessary. Date Code 20160329 SEL-651RA Recloser Control...
  • Page 4: Wiring With Fuse Block

    Step 4. Attach the 8-pin harness wires according to the table in Figure 6 as required for your specific secondary input voltage option. See Table 1 for SIV-specific wiring. SEL-651RA Recloser Control Date Code 20160329...
  • Page 5 Brown Wire (F, Heatshrink) V2Z - Bottom Red Wire (G, Heatshrink) V3Z - Bottom Orange Wire (H, Heatshrink) NZ - Bottom Figure 6 Attach Wires to Fuse Block Step 5. Zip tie wires as necessary. Date Code 20160329 SEL-651RA Recloser Control...
  • Page 6: Wiring Diagrams

    Wiring Diagrams Without Fuse Block Drain Ground Stud SEL-651RA Recloser Control Date Code 20160329...
  • Page 7 With Fuse Block Drain Ground Stud Wiring between fuse block and control module not shown. Date Code 20160329 SEL-651RA Recloser Control...
  • Page 8: Factory Assistance

    All brand or product names appearing in this document are the trademark or regis- 2350 NE Hopkins Court • Pullman, WA 99163-5603 U.S.A. tered trademark of their respective holders. No SEL trademarks may be used with- Tel: +1.509.332.1890 • Fax: +1.509.332.7990 out written permission.