CONTENTS GENERAL INFORMATION AND SAFETY ....4 APPLICATION............4 OPERATION ............4 ........4 PERATION OF THE PANEL ............. 5 AIN SCREEN ..........5 PERATION MODES 3.3.1 Schedule ............5 3.3.2 Economy ............. 5 3.3.3 Comfort ............5 3.3.4 Out of home ..........5 3.3.5 Airing ............
controller with a touch panel or remote 1. General information and safety screen internal temperature sensor enables reading and programming temperature with an accuracy of 0.1°C. can be programmed in 7-day cycle with an accuracy of 0.5h which is equal to 48 ...
8. Current external temperature (available Main screen only with a weather sensor connected to the boiler controller). 9. Current level of fuel inside the boiler feeder. 10. Current preset temperature inside the compartment. 11. Number of available main screens with indication which currently...
operating before the Outside home mode Activation of this mode will additionally result was set. in setting a preset temperature of hot utility water on the ecoMAX boiler controller to 8˚C symbol is displayed on the screen. symbol is displayed on the screen. 3.3.5 Airing 3.3.9 Loading HUW Selection of this mode will result in closing...
If the boiler controller is equipped with a standard control panel (version with a knob), Press button in order to display the ecoSTER TOUCH room panel will display window for copying the set schedule to a precise graphic image of the controller any weekday.
3.12.3 Screen brightness 3.12.8 Sound Enables setting screen backlight Activation/deactivation of sound in brightness in [%] separately for a day (6:00- alarms and notifications sent by the boiler 22:00), night (22:00-6:00) and the current controller. edition of settings. 3.12.9 Clock 3.12.4 Changing the language Setting the current time.
etc. It facilitates determining location of panel inside building changing preset temperature in a distant room. This name will be additionally visible on screens of other room panels. Selected panel Address (at 2 or 3 connected panels) is displayed on the main screen as (further digits 2,3).
Manufacturer bears responsibility 4. ASSEMBLY damages caused by non-observance of this manual. Technical data Power supply/consumed +12VDC/150mA Assembly description current Protection class IP20 Drill holes in the wall (apply rawlplugs in 0..50/0..65 C Work/storage temperature case of masonry wall) and screw the Temperature 0..50/5..35 C screws in.
If not, use an additional power adaptor +12VDC, I≥0.5A. Depending on the ecoMAX boiler controller software version, it can cooperate with only one or max. three ecoSTER TOUCH room panels. Further chapters describe the method of connecting ecoSTER TOUCH room panel/panels to various ecoMAX series boiler controller modules.
4.5.2 Connection with ecoMAX800 P3, ecoTOUCH control panel (colored with a D3 and ecoMAXX800 R3, T3 touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 31). Panels 2...
If the boiler controller is equipped with 4.5.4 Connection with ecoMAX850P2, ecoTOUCH control panel (colored with a R2, D2 touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 40). Panels 2...
If the boiler controller is equipped with 4.5.5 Connection with ecoMAX860P1, ecoTOUCH control panel (colored with a touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 46). Panels 2...
4.5.6 Connection with ecoMAX860P2, If the boiler controller is equipped with ecoTOUCH control panel (colored with a touch panel), only one ecoSTER TOUCH room Controller module can supply up panel can be supplied directly from the to 2 colored TOUCH type panels controller module (socket G4).