Plum ecoSTER TOUCH Operation And Assembly Manual

Plum ecoSTER TOUCH Operation And Assembly Manual

Room panel for ecomax boiler controller
Hide thumbs Also See for ecoSTER TOUCH:

Advertisement

ROOM PANEL
ecoSTER TOUCH
FOR ECOMAX BOILER CONTROLLER
OPERATION AND ASSEMBLY MANUAL
ISSUE: 1.0
SOFTWARE VERSION: v01.XX.XX
10-2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecoSTER TOUCH and is the answer not in the manual?

Questions and answers

Summary of Contents for Plum ecoSTER TOUCH

  • Page 1 ROOM PANEL ecoSTER TOUCH FOR ECOMAX BOILER CONTROLLER OPERATION AND ASSEMBLY MANUAL ISSUE: 1.0 SOFTWARE VERSION: v01.XX.XX 10-2015...
  • Page 3: Table Of Contents

    CONTENTS GENERAL INFORMATION AND SAFETY ....4 APPLICATION............4 OPERATION ............4 ........4 PERATION OF THE PANEL ............. 5 AIN SCREEN ..........5 PERATION MODES 3.3.1 Schedule ............5 3.3.2 Economy ............. 5 3.3.3 Comfort ............5 3.3.4 Out of home ..........5 3.3.5 Airing ............
  • Page 4: General Information And Safety

    controller with a touch panel or remote 1. General information and safety screen internal temperature sensor enables reading and programming temperature with an accuracy of 0.1°C. can be programmed in 7-day cycle with an accuracy of 0.5h which is equal to 48 ...
  • Page 5: Main Screen

    8. Current external temperature (available Main screen only with a weather sensor connected to the boiler controller). 9. Current level of fuel inside the boiler feeder. 10. Current preset temperature inside the compartment. 11. Number of available main screens with indication which currently...
  • Page 6: Airing

    operating before the Outside home mode Activation of this mode will additionally result was set. in setting a preset temperature of hot utility water on the ecoMAX boiler controller to 8˚C symbol is displayed on the screen. symbol is displayed on the screen. 3.3.5 Airing 3.3.9 Loading HUW Selection of this mode will result in closing...
  • Page 7: Temperature Settings

    If the boiler controller is equipped with a standard control panel (version with a knob), Press button in order to display the ecoSTER TOUCH room panel will display window for copying the set schedule to a precise graphic image of the controller any weekday.
  • Page 8: Screen Brightness

    3.12.3 Screen brightness 3.12.8 Sound Enables setting screen backlight Activation/deactivation of sound in brightness in [%] separately for a day (6:00- alarms and notifications sent by the boiler 22:00), night (22:00-6:00) and the current controller. edition of settings. 3.12.9 Clock 3.12.4 Changing the language Setting the current time.
  • Page 9: Information

    etc. It facilitates determining location of panel inside building changing preset temperature in a distant room. This name will be additionally visible on screens of other room panels. Selected panel Address (at 2 or 3 connected panels) is displayed on the main screen as (further digits 2,3).
  • Page 10: Assembly

    Manufacturer bears responsibility 4. ASSEMBLY damages caused by non-observance of this manual. Technical data Power supply/consumed +12VDC/150mA Assembly description current Protection class IP20 Drill holes in the wall (apply rawlplugs in 0..50/0..65 C Work/storage temperature case of masonry wall) and screw the Temperature 0..50/5..35 C screws in.
  • Page 11: Module

    If not, use an additional power adaptor +12VDC, I≥0.5A. Depending on the ecoMAX boiler controller software version, it can cooperate with only one or max. three ecoSTER TOUCH room panels. Further chapters describe the method of connecting ecoSTER TOUCH room panel/panels to various ecoMAX series boiler controller modules.
  • Page 12: Connection With Eco Max800 P3, D3 And

    4.5.2 Connection with ecoMAX800 P3, ecoTOUCH control panel (colored with a D3 and ecoMAXX800 R3, T3 touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 31). Panels 2...
  • Page 13: Connection With Eco Max850P2, R2, D2

    If the boiler controller is equipped with 4.5.4 Connection with ecoMAX850P2, ecoTOUCH control panel (colored with a R2, D2 touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 40). Panels 2...
  • Page 14: Connection With Ecomax860P1, D1

    If the boiler controller is equipped with 4.5.5 Connection with ecoMAX860P1, ecoTOUCH control panel (colored with a touch panel), only one ecoSTER TOUCH room panel can be supplied directly from the Controller module can supply up to controller module (terminal 46). Panels 2...
  • Page 15: Connection With Ecomax860P2, D2

    4.5.6 Connection with ecoMAX860P2, If the boiler controller is equipped with ecoTOUCH control panel (colored with a touch panel), only one ecoSTER TOUCH room Controller module can supply up panel can be supplied directly from the to 2 colored TOUCH type panels controller module (socket G4).
  • Page 16 Tel: 0264 241 234 Str.Armeneasca,Nr. 59,Gherla,Jud.Cluj...