4100ES PIDs (continued)
Telephones/
The following phone and microphone assemblies are used with audio operator interfaces.
Microphones
•
•
•
•
•
•
Additional Audio
Optional modules for the 4100ES audio system are listed below.
Modules
•
•
•
•
•
•
•
Common Audio
•
Options
•
•
•
•
•
•
•
•
•
Amplifiers
Note: The following amplifiers are used only in the 4100U and 4100ES systems, and are not compatible
100 W Analog Amplifiers:
•
•
•
•
•
•
•
•
4100-1270 Master Telephone with Phone Card and 3 NACs (742-865)
4100-1271 Remote Master Telephone (742-597)
4100-1243 Microphone (742-523)
4100-1244 Remote Microphone (742-821)
4100-1265 Degraded Fail-Safe Mode Microphone Pre-Amp (Master – 743-238)
4100-1269 Degraded Fail-Safe Mode Microphone Pre-Amp (Slave – 743-306)
4100-0623 Network Audio Interface Module (742-522)
4100-1240 Aux Audio Input Board (742-388)
4100-1241 Audio Message Memory Expansion Module, 8 Minute (742-518)
4100-1242 Audio Message Memory Expansion Module, 32 Minute (742-393)
4100-1272 Telephone Expansion Card (742-600)
4100-1273 Class A Telephone Adapter Module (742-599)
4100-1274 Microphone Mux Module (743-808)
4100-1245 Flex 50 Expansion NAC Board with 3 Class B NACs (742-540)
4100-1246 Flex 50 Class A Adapter (Converts 3 on-board NACs to Class A) (742-539)
4100-1248 100 Watt Expansion NAC Board with 6 Class B NACs (742-524)
4100-1249 100 Watt Class A Adapter (Converts 6 on-board NACs to Class A) (742-543)
4100-1259 Constant Supervision NAC 25 VRMS with 3 Class A/B Constant Supervision
NACs (Converts 3 on-board NACs to Constant Supervision) (743-163)
4100-1260 Constant Supervision NAC 70 VRMS with 3 Class A/B Constant Supervision
NACs (Converts 3 on-board NACs to Constant Supervision) (743-164)
4100-1266 Expansion Signal Card Expansion NAC Board with 3 Class B NACs
(743-302)
4100-1267 Expansion Signal Card Class A Adapter (Converts 3 on-board NACs to
Class A (743-303)
4100-1268 Expansion Signal Card Constant Supervision NAC Adapter, 25 or 70 VRMS
with 3 Class A/B Constant Supervision NACs (Converts 3 on-board NACs to Constant
Supervision) (743-304)
4100-5116 Expansion Signal Card with 3 Class B NACs (743-159)
with the Constant Supervision NAC (CSNAC) option.
4100-1214 Amp – 120 VAC, 25 VRMS (742-550)
4100-1215 Amp – 120 VAC, 70 VRMS (742-551)
4100-1216 Amp – 120 VAC, 25 VRMS – Canada (742-552)
4100-1217 Amp – 120 VAC, 70 VRMS – Canada (742-553)
4100-1218 Amp – 220/230/240 VAC, 25 VRMS (742-554)
4100-1219 Amp – 220/230/240 VAC, 70 VRMS (742-555)
4100-1220 Backup Amp – 120 VAC, 25 VRMS (742-550)
4100-1221 Backup Amp – 120 VAC, 70 VRMS (742-551)
Chapter 1 Introduction to the 4100ES Fire Alarm System
1-18
Continued on the next page