Mitsubishi Electric FX2N-20GM User Manual
Mitsubishi Electric FX2N-20GM User Manual

Mitsubishi Electric FX2N-20GM User Manual

Melsec-f fx2n series
Hide thumbs Also See for FX2N-20GM:

Advertisement

Quick Links

This manual only describes the specifications for FX
For complete operation, wiring, mounting and programming instructions please refer to the FX
FX
-20GM HARDWARE PROGRAMMING MANUAL, FX PROGRAMMING MANUAL and FX SERIES
2N
HARDWARE MANUAL.
These manuals should be read and understood before attempting to install or use the unit.
And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always
forward it to the end user.
Safety Precaution
This manual classifies the safety precautions into two categories:
Indicates that incorrect handling may cause hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
It is important to follow all precautions for personal safety
DESIGN PRECAUTIONS
Install a safety circuit outside the PLC so that the entire system conservatively operates even if an
abnormality occurs in the external power supply or a failure occurs in the PLC.
If the safety circuit is installed inside the PLC, malfunction and erroneous output may cause accidents.
STARTUP AND MAINTENANCE
PRECAUTIONS
Do not touch any terminal while the FX
Doing so may cause electric shock or malfunctions.
Before cleaning or retightening terminals externally cut off all phases of the power supply.
Failure to do so may cause electric shock.
Use the battery for memory backup correctly in conformance to the FX
HARDWARE PROGRAMMING MANUAL.
-
Use the battery only for the specified purpose.
-
Connect the battery correctly.
-
Do not charge, disassemble, heat, put in fire, short-circuit, connect reversely, weld, swallow or
burn the battery, or apply excessive forces (vibration, impact, drop, etc.) to the battery.
-
Do not store or use the battery at high temperatures or expose to direct sunlight.
-
Do not expose to water, bring near fire or touch liquid leakage or other contents directly.
-
Incorrect handling of the battery may cause heat excessive generation, bursting, ignition,
liquid leakage or deformation, and lead to injury, fire or failures and malfunctions of facilities
and other equipment.
Thoroughly read the manual, sufficiently confirming safety, then perform returning to the zero point
in the MANU/AUTO mode, jog operation, step operation or automatic operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND MAINTENANCE
PRECAUTIONS
Turn off the power to the FX
memory board. If the memory board is attached or detached while the FX
controller's power is on, the data in the memory may be destroyed, or the memory board may be
damaged.
Do not disassemble or modify the FX
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric distributor.
Turn off the power to the FX
extension cable.
Failure to do so may cause equipment failures or malfunctions.
Turn off the power to the FX
following devices.
Failure to do so may cause equipment failures or malfunctions.
-
Peripheral devices, extension blocks, FX Series terminal blocks, Battery and memory board
(Read these precautions before use.)
-20GM positioning controller before attaching or detaching the
2N
2N
-20GM positioning controller before connecting or disconnecting any
2N
-20GM positioning controller before attaching or detaching the
2N
FX
USER'S GUIDE
JY992D77601K
-20GM positioning controller.
2N
-20GM positioning controller's power is on.
2N
-20GM positioning controller.
-20GM
2N
and
may also cause severe injury.
-10GM, FX
2N
-20GM positioning
2N
-10GM,
2N
.
-20GM
2N

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric FX2N-20GM

  • Page 1 Do not disassemble or modify the FX -20GM positioning controller. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric distributor. • Turn off the power to the FX -20GM positioning controller before connecting or disconnecting any extension cable.
  • Page 2: Disposal Precautions

    DISPOSAL PRECAUTIONS • Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device. When disposing of batteries, separate them from other waste according to local regulations. (For details of the Battery Directive in EU countries, refer to FX -10GM, FX -20GM HARDWARE PROGRAMMING MANUAL)
  • Page 3: Product Composition

    4. Product composition 4.1 Each part name The name and description of each part of the FX -20GM are explained below. a) Battery k) Connector for PLC extension block b) Operation indicator LED l) Hook for DIN rail installation c) MANU/AUTO switch m)Connector for y axis motor amplifier: CON4 d) Connector for programming tool n) Connector for x axis motor amplifier: CON3...
  • Page 4: Specification

    4.5 I/O extension connector The FX -20GM can connect the following extension block. 1) FX series extension block - FX -16EX-DS - FX -16EYT-DSS - FX -32EX-DS - FX -32EYT-DSS - FX -16EX-T-DS - FX -16EX-D/UL - FX -16EYT-D/UL - FX -32EX-D/UL - FX -32EYT-D/UL...
  • Page 5: Input Specifications

    Item Contents Noise immunity 1,000Vp-p, 1µs. 30 to 100Hz, tested by noise simulator. Dielectric withstand 500V AC > 1 min, tested between all points, terminal and ground. voltage Insulation resistance 5MΩ > 500V DC, tested between all points, terminal and ground Ground Class D grounding (100Ω...
  • Page 6: Warranty

    This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 7 Din rail width: 35mm Doing so may cause fire, equipment failures, or malfunctions. Input block Install a safety circuit Weight: approx.0.4kg For repair, contact your local Mitsubishi Electric distributor. outside of FX -20GM so Dimensions mm(inch) • Turn off the power to the FX...
  • Page 8 Mechanical system: DOG (near-point signal), 2) Remove side cover from the FX -20GM. confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any LSF (forward rotation limit), LSR (reverse rotation limit), Control inputs 3) Remove battery from holder-disconnect and replace. (This must be carried out within 30 sec if the cur-...

Table of Contents