Parameter clear

3.22 Parameter clear
POINT
· Set "1" in Pr.CL parameter clear to initialize all parameters. (Parameters are not cleared when "1" is set in Pr. 77
Parameter write selection.)
1.
Screen at powering on
The monitor display appears.
2.
Press
mode.
3.
Press
setting mode.
4.
Turn
until "
appears.
5.
Press
"
"(initial value) appears.
6.
Turn
clockwise to change it to
the setting value of " ".
7.
Press
Setting
0
Not executed.
Returns all parameters except calibration parameters
1
C0 (Pr. 900) to C7 (Pr. 905) to the initial values. *
* Pr.73, Pr.75, Pr.90, Pr.125, Pr.126, Pr.161, Pr.170 to Pr.174, Pr.178 to Pr.196, Pr.255 to Pr.258, Pr.267, Pr.343, Pr.496, Pr.497, Pr.503,
Pr.504, Pr.888, Pr.889, Pr.989 are not cleared.
and
The inverter is not in the PU operation mode. Press
from step 6 again.
220
Operation
to choose the PU operation
to choose the parameter
" (parameter clear)
to read the currently set value.
to set.
· Turn
to read another parameter.
· Press
to show the setting again.
· Press
twice to show the next parameter.
Description
are displayed alternately ... Why?
Display
PU indication is lit.
Flicker ··· Parameter setting complete!!
to lit
The parameter
number read
previously appears.
, then carry out operation