3.16.2 Parameter write disable selection (Pr.77)

You can select whether write to various parameters can be performed or not. Use this function to prevent
parameter values from being rewritten by misoperation.
Parameter
Name
Number
77
Parameter write selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 140.)
Pr. 77 can be always set independently of the operation mode and operation status.
(1) Write parameters only at a stop (setting "0", initial vale)
⋅ Parameters can be written only during a stop in the PU operation mode.
⋅ The parameters marked in the parameter list (page 38)
mode and operation status. However, Pr. 72 PWM frequency selection and Pr. 240 Soft-PWM operation selection can
be written during operation in the PU operation mode, but cannot be written in external operation mode.
(2) Disable parameter write (Setting "1")
⋅ Parameter write is not enabled. (Reading is
enabled.)
⋅ Parameter clear and all parameter clear cannot be
performed, either.
⋅ The parameters given on the right can be written if
Pr. 77 = "1".
(3) Write parameters during operation (Setting "2")
⋅ Parameters can always be written.
⋅ The following parameters cannot be written during operation if Pr. 77 = "2". Stop operation when changing their
parameter settings.
Parameter
Number
19
Base frequency voltage
23
Stall prevention operation level compensation factor at double speed
48
Second stall prevention operation current
49
Second stall prevention operation frequency
60
Energy saving control selection
66
Stall prevention operation reduction starting frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity (simple magnetic flux vector control)
90
Motor constant (R1)
100 to 109
(Adjustable 5 points V/F parameter)
135
Power-supply switchover sequence output terminal selection
136
MC switchover interlock time
137
Waiting time at a start
138
Commercial power-supply operation switchover selection at an alarm
139
Automatic switchover frequency between inverter and commercial power-supply operation
178 to 196
(I/O terminal function selection)
255
Life alarm status display
256
Inrush current suppression circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
329
Digital input unit selection (Parameter for the plug-in option FR-A7AX)
343
Communication error count
563
Energization time carrying-over times
564
Operating time carrying-over times
570
Multiple rating setting
♦ Parameters referred to ♦
Pr. 79 Operation mode selection
Initial Value
0
Refer to page 142
Misoperation prevention and parameter
Setting
Range
0
Write is enabled only during a stop.
1
Parameter write is not enabled.
Parameter write is enabled in any operation
2
mode regardless of operation status.
can always be written, regardless of the operation
Parameter
Number
22
Stall prevention operation level
Reset selection/disconnected PU
75
detection/PU stop selection
77
Parameter write selection
79
Operation mode selection
Name
setting restriction
Description
Name
139
Pr.76
page 116
Pr.78
page 140
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents