COMPONENT
CHECKOUT
procedure
RESULT
Measure
the resistance:
Across two terminals
Normal
reading:
with an ohm-meter
on highest scale.
Momentarily
indicates
several
ohms,
and
gradually
returns to 10 meg-ohms.
Abnormal
reading:
HIGH-VOLTAGE
CAPACITOR
Indicates
continuity
or 10 meg-ohms
from
Wfi
~
the beginning.
including
BLEEDER
ohm-meter
Q
RESISTOR
Figure
7
Measure
the resistance:
Across two terminals
Normal
reading:
with an ohm-meter
on R x 10,000
scale.
Indicates
about
the middle
position
in one
direction
(forward
direction)
and
infinite
ohms
in the
reverse direction,
using meter
/
m
which
is provided
with
a 9-volt
battery.
ohm-meter
6Y
NOTE
HIGH-VOLTAGE
Some
digital
meter
may
show
over even
DIODE
"0
;--m&
in a forward
direction
because low measur-
ing voltage
of
meter
does
not
allow
the
meter
current
to
pass through
the
high
voltage diode.
Figure
8
Abnormal
reading:
Indicates
continuity
or infinite
ohms in both
directions.
Measure
The resistance:
Across two
terminals
Normal
reading:
with an ohmmeter
on highest scale.
Indicates
infinite
ohms in both directions.
/
A
m
Abnormal
reading:
Ohm-meter
Indica[es
continuity
in both
directions
or
FUSE
DIODE
continuity
in
one
direction
and
infinite
ohms
in
reversed
direction.
Figure
9
Measure
the
voltage:
Between
test points
TP-1,
TP-2,
or TP-3 and ground
or between
TP-4
and
TP-5.
(See control
circuit
board
Test
TP- 1
TP-2
TP-3
TP-4/
on page 19)
Point
TP.5
CONTROL
-5V
–12V
–30V
CIRCUIT
BOARD
Voltage
Dc
2.OV
NOTE
DC
DC
AC
4
-
Proceed
with
the check of the step-down
transformer,
to see if any one of the measur-
ed
values
is different
from
the
specified
values.