STEP 4CS
Note: Clack Twin Alternator Operations
• Twin alternating systems can be programmed with a day override setting combined with the normal volume-based regeneration
programming. A twin alternating system in this confi guration will then regenerate based on the volume used or the day override if there is
a period of low water usage.
• Twin alternating systems can be programmed as a time clock only based regenerating system. In this confi guration, the days remaining are
counted only on the unit that is in service. The unit in Stand-by Mode only notes days in diagnostics, which results in time clock only twin
regeneration initiation.
• Twin alternating systems can be programmed for a delayed regeneration time. The system will allow an immediate transfer of the MAV
to switch tanks and place a fully regenerated unit in service once a unit becomes exhausted. The exhausted unit will then be placed into
Stand-by Mode and allowed to have a delayed regeneration at the pre-set time.
Step 4CS – Allows selection of one of the following using the
• the Control Valve to act as an alternator; or
• the Control Valve to have a no hard water bypass: or
• the Control Valve to have a Separate Source during the regeneration cycle; or
• the Control Valve to operate with the Clack System Controller.
Select OFF when none of these features are used.
Only use Clack No Hard Water Bypass Valves or Clack Motorized Alternating Valves (MAV) with these
selections. Clack No Hard Water Bypass Valves (1" or 1.25" V3070FF or V3070FM) are not designed
to be used with the alternator function or separate source.
Selecting the Control Valve to act as an alternator:
Prior to starting the programming steps, connect the interconnect cable to each control valve board's
three pin connector labeled "INTERCONNECT". Also connect the meter cord to either control valve
OEM Confi guration
Step 4CS
Setup
Softener System
Setup
Softener System
Step 10S
Setup
Installer Display
Setting
Valve "A" in Service Position =
MAV piston rod Retracted
to the three pin connector labeled "METER".
Softener valve programming steps
Set to ALTA
Connect ALTA valve to the MAV's
A port and connect the MAV's two
pin wire connector to the two pin
connector labeled "MAV DRIVE"
on the ALTA valve
Step 9S
Set to "AUTO"
Set regeneration time option to
"IMMEDIATE".
Step 3I
Set Day Override to "OFF"
Retracted
or
buttons:
Set to ALTB
Connect ALTB
valve to the
MAV's B port.
No connections
between the
ALTB valve and the
MAV are made.
Set to "AUTO"
Set regeneration
time option to
"IMMEDIATE".
Set Day Override to
"OFF"
Extended
Valve "B" in Service Position = MAV
piston rod Extended
Page 53