Samsung DECT 500 Installation And Programming Manual page 45

Table of Contents

Advertisement

Part 2: DECT Hardware Installation and Programming
Note 3: When the base station is a residential single cell base station, the valid RPN is in the range 2–7.
When the Repeater is used on a PABX or public system, the RPN may be in the range 0–255. In this case,
the Repeater accepts up to three digits entered. The last three valid digits only are recorded.
Note 4: If the #-key is used to accept the subscription identities, an inspection tone is enabled. The Repeater
will then, when relaying connections, insert a short tone every two seconds in the audio path to handsets.
This feature can be used for inspection and verification of the Repeater placement. When the operation has
been verified, the inspection tone should be disabled. Performing step 2 only of the subscription procedure
will disable the inspection tone. When the LED has started flashing in subscription mode, switch off the Re-
peater and then on again. The Repeater is then back in normal mode without affecting the subscription identi-
ties and the inspection tone has been disabled.
40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dect 1500

Table of Contents