Product Identification - ABB Fulscope 76J Series Model C Instructions Manual

Table of Contents

Advertisement

1.3

PRODUCT IDENTIFICATION

The serial number stamped on the data plate consists of the catalog number and a sequential
identification number. The catalog number describes the construction of the recorder.
For measuring element actuation ordering information, refer to the appropriate specification
Sheet located in the Measuring Element tab section.
Code No.
Description
BASE NUMBER - 1st through 3rd Characters
76J
FULSCOPE Recorder
NUMBER OF RECORDING PENS - 4th Character
1
1 Pen
2
2 Pens
3
3 Pens
PEN 1 MEASURING ELEMENT TYPE - 5th Character
Temperature (filled system) Fill fluid:
G
Gas, SAMA class IIIB
M
Mercury, SAMA class VA and VB
V
Vapor, SAMA class II A, B, C, or, D
R
Monolex™, SAMA class IB
S
Ducalex™, SAMA class IA
Pressure Elements (letter codes, C, J, P, and Z are ALWAYS installed in the
upper left (second pen) position. For 2 or 3 pen instruments they can only be in
pen 2 position)
A
Absolute Pressure Capsule
C
Differential Pressure meter body. Termination's 183 through 186: see pen 2 code.
can only be selected once per instrument
Z
Differential Pressure meter body. Termination's 191 through 197 see pen 2 code. can
only be selected once per instrument
D
Differential Pressure: Low Pressure unit
F
Gauge Pressure: low pressure units or Bourdon Springs
N
Gauge Pressure: Remote seal Filled system
Electrical input to motion converter
T
Electrical to motion element
Measuring element not included
L
Set-up for but no supply measuring element. Not valid for set-up for type 183 to 186,
and 191 to 197 Differential pressure meter body.
J
Set-up for but no supply type 183 to 186 Differential pressure meter body
P
Set-up for but no supply type 191 to 197 Differential pressure meter body
PEN 2 MEASURING ELEMENT TYPE - 6th Character
O
Second pen not installed
Temperature (filled system) Fill fluid:
G
Gas, SAMA class IIIB
M
Mercury, SAMA class VA and VB
V
Vapor, SAMA class II A, B, C, or, D
R
Monolex™, SAMA class IB
S
Ducalex™, SAMA class IA
76J Pneumatic Fulscope Recorder
INTRODUCTION
3

Advertisement

Table of Contents
loading