N o t e
Reconfigure the MAC Age Time for Learned MAC Addresses. This
command corresponds to the MAC Age Interval in the menu interface, and is
expressed in seconds.
Syntax: mac-age-time < 10 - 1000000 > (seconds)
For example, to configure the age time to seven minutes:
HPswitch(config)# mac-age-time 420
Configure the Time Zone and Daylight Time Rule. These commands:
Set the time zone you want to use
Define the daylight time rule for keeping the correct time when daylight-
saving-time shifts occur.
Syntax: time timezone < -720 - 840 >
time daylight-time-rule < none | alaska | continental-us-and-canada |
middle-europe-and-portugal | southern-hemisphere | western-europe |
user-defined>
East of the 0 meridian, the sign is "+". West of the 0 meridian, the sign is "-".
For example, the time zone setting for Berlin, Germany is +60 (zone +1, or 60
minutes), and the time zone setting for Vancouver, Canada is -480 (zone -8, or
-480 minutes). To configure the time zone and daylight time rule for Vancouver,
Canada:
HPswitch(config)#
continental-us-and-canada
Configure the Time and Date. The switch uses the time command to con-
figure both the time of day and the date. Also, executing time without param­
eters lists the switch's time of day and date. Note that the CLI uses a 24-hour
clock scheme; that is, hour (hh) values from 1 p.m. to midnight are input as
13 - 24, respectively.
Syntax: time [ hh:mm [ :ss ]] [ mm/dd/ [ yy ] yy ]
For example, to set the switch to 9:45 a.m. on November 17, 2002:
HPswitch(config)# time 9:45 11/17/02
Executing reload or boot resets the time and date to their default startup values.
Interface Access and System Information
time timezone -480 daylight-time-rule
System Information
7-13