4.1
Outline
4.2
How to go CD TEST MODE
[STOP] + [CD] + AC in
4.3
Function specification
Function
CD TEST MODE
C1 error display
C1 error display
Return to CD TEST MODE
4.4
C1 error history
When 8 key is pressed, syscon send C1 err display command (0x9C 0x01 0x00).
If syscon receive C1 error display status (0xAA 0x01 0x00 ** **), it displays C1 error.
Syscon convert 2byte hex data to decimal data (00000-65635).
4.5
Special mode
[POWER] + [SET] + [REPEAT]: COLD SET
[POWER] + [SET] + [S.TURBO]: FL DISPLAY turn on all segment
[POWER] + [SET] + [BASS/TRE]:Micon version display
press again and again
1-20 (No.MB665<Rev.004>)
SECTION 4

ADJUSTMENT

CD TEST MODE
C1 error display
Key
Operation
C
>>|
Remocon
I
Remocon
E
CANCEL
Remocon
C
Syscon version
CD version
USB version
Destination
Model name
FL display
D
T
E
S
T
T
N
I
T
I
A
L
r
*
*
*
*
*
D
T
E
S
T
T
After receive data