Cam Auto-Generation Function (B-30008) - Mitsubishi Electric MELSEC-Q Series Manual

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

5.3.8 Cam Auto-generation Function (B-30008)

1
Outline
This is the QD77MS16 cam auto-generation screen.
Description
1.
Sets parameters that are required for cam auto-generation.
2.
Executes cam generation.
3.
Switches to each screen. The blue switch indicates the currently displayed screen, thus selecting this
switch will not switch the screen.
4.
Switches to the previously opened screen.
5.
Displays the current date and time. Touch the area to open the [Clock Setting] window.
6.
Opens the [Language Setting] window.
Remarks
 If a system alarm occurs, the alarm message will appear at the bottom of the screen. When touching the left
end of the message, the display position of the message changes in the order of upper, center, and lower.
When touching the other part of the message, the [Alarm Reset] window appears.
 When GOT is started, the cam auto-generation type device is set to 1 with the project script. For more
details about scripts, please refer to "5.6 Script List".
3
16/35
5
6
2
4
BCN-P5999-0176-2a