Do you have a question about the FT-65R and is the answer not in the manual?
Questions and answers
Frank Cihak
March 8, 2025
Factory reset
1 comments:
Mr. Anderson
March 8, 2025
The provided context mentions that performing a factory reset on the Yaesu FT-65R can revert expanded TX settings, but it does not provide the exact steps for a factory reset. The manual reference suggests an "All Reset" procedure, which clears all settings, including passwords and memories. However, the exact steps to perform a factory reset are not detailed in the context.
Page 1
144/430 MHz DUAL BAND TRANSCEIVER FT-65 FT-65 Advance Manual Clicking (tapping) the at the bottom right of the current browsing page, will return to the contents page at any time.
About this manual This manual provides information to assist in using the many FT-65R/E useful and convenient features. Refer to this Advance Manual along with the Operating Manual. This manual contains symbols and conventions to call attention to important in- formation.
4. Press the [▲] or [▼] key to select the desired signal strength level for the squelch threshold (S-1, S-2, S-3, S-4, S-5, S-6, S-8, S-FULL, or OFF). 5. Press the PTT switch to save the new setting and return to normal operation. FT-65R/FT-65E Advance Manual...
Checking the Battery Voltage The FT-65R/E microprocessor includes programming which will measure the current battery voltage. 1. Press and hold the key to enter the Set Mode. 2. Press the [▲] or [▼] key to select Set Mode Item “10 DC VOLT”.
4. Press the [▲] or [▼] key to select “VOX ON” or “VOX OFF (default setting)”. 5. Press the PTT switch to save the new setting and return to normal operation. When the VOX system is activated, the “ ” icon will appear on the display. FT-65R/FT-65E Advance Manual...
To modify the VFO-B (transmit) frequency (for Doppler Shift correction, etc.), just press the [ V/M] key, make the necessary change, and then press the [ V/M] key once more to restore VFO-A to the “receive VFO” position. FT-65R/FT-65E Advance Manual...
FM carrier in order to activate the repeater. This helps prevent false activation of the repeater by radar or spurious signals from other transmitters. This tone system, called “CTCSS” (Continuous Tone Coded Squelch System), is included in the FT-65R/E. The CTCSS is very easy to activate.
6. When you have made your selection, press the F key to save the desired tone fre- quency. 7. Press and hold the F key to move the upper menu contents in the Set Mode. 8. Press the PTT switch to return to normal operation. FT-65R/FT-65E Advance Manual...
4. Press the [▲] or [▼] key to set the desired number of Bell rings. The available choices are “1Time”, “3Times”, “5Times”, “8Times”, “CONTINUE” (continuous ringing), or “OFF (default setting)”. 5. Press the PTT switch to save the new setting and return to normal operation. FT-65R/FT-65E Advance Manual...
Using the Squelch Feature EPCS (Enhanced Paging & Code Squelch) The FT-65R/E includes an Enhanced CTCSS tone encoder/decoder and a dedicated microprocessor providing paging and selective calling features. The squelch permits directing calls to specific stations (Paging), and receiving only the calls directed to stations programmed with a similar code (Code Squelch).
3. To disable the EPCS function, just repeat the above procedure, Press the [▲] or [▼] key to select “OFF” in step 1 above. During EPCS operation, the FT-65R/E may be set up to sound a ringing “bell” alert when an EPCS call is coming in, as described previously. See page 10 for details.
Using the Squelch Feature Paging Answer Back When the PTT switch is pressed in response to answer a paging call, the FT-65R/E transmits the same CTCSS tone pair. This tone pair will open the Code Squelch of the calling station. If preferred, the FT-65R/E may be setup to respond to the pager calls automatically (“transpond”).
Memory Bank Operation The large number of memories available in the FT-65R/E could be difficult to manage without some means of organizing them. Fortunately, the FT-65R/E includes a provision to divide the memories into as many as ten Memory Groups. The memories can be categorized in a manner convenient for the operator.
• If assigned memory channels still remain in the Memory Bank, the display will return to a Memory Bank channel. • If there is no assigned memory channel in the Memory Bank, the display will return to the Memory channel. FT-65R/FT-65E Advance Manual...
When the LCD backlight is on, release the MONI/T.CALL key and the PTT switch. 3. Press the [▲] or [▼] key to select “F5:MEM-ONLY”. 4. Press the F key momentarily to complete the procedure. To return to normal operation, repeat the above power-on procedure. FT-65R/FT-65E Advance Manual 16...
5. Press the PTT switch to return to normal operation. When the “skipped” memory channel is manually recalled, the “ ” icon will appear below the memory channel number, indicating it is to be ignored during scanning. FT-65R/FT-65E Advance Manual 17...
When the Weather Alert Scan feature is engaged in the VFO mode, or the Memory mode, the FT-65R/E will check the Weather Broadcast Memory Channels for the NOAA Alert Tone every five seconds while scanning. the display will be observed periodically shifting...
10 pairs of Band Limit memories, labeled L01/U01 through L10/U10 are available. Therefore upper and lower operating limits may be set for multiple segments on a number of bands, if you like. FT-65R/FT-65E Advance Manual...
4. Press the F key, then press the [ V/M] key again to disable the Memory Priority Mode. When the Memory Bank feature is activated, the FT-65R/E will check the lowest memory channel number in the current Memory Bank as the priority channel.
3. Press the F key to enable adjustment of this item. 4. Press the [▲] or [▼] key to select “RVT . ON” or “RVT . OFF (default setting)”. 5. Press the PTT switch to save the new setting and return to normal operation. FT-65R/FT-65E Advance Manual...
Scanning Automatic Lamp Illumination on Scan Stop The FT-65R/E will automatically illuminate the LCD/Keypad Lamp whenever the scanner stops on a signal; this allows you to see the frequency of the incoming signal better at night. Note that this will, of course, increase the battery consumption, so be sure to switch it off during the day (the default setting is “ON”).
Emergency Channel Operation The FT-65R/E includes an “Emergency” feature which may be useful if you have someone monitoring on the same frequency as your transceiver’s VHF “Home” channel. See FT- 65R/E Operating Manual for details on setting the Home channel.
1. Set all the transceivers to the same DCS code number, per the instructions on page 2. Press and hold the [2] key. • “OUT.RNG” will be displayed on the LCD. • ARTS polling will begin. 3. Every 25 seconds, the transceiver will transmit a “polling” call to the other station. FT-65R/FT-65E Advance Manual 24...
1. Press and hold the F key to enter the Set mode. 2. Press the [▲] or [▼] key to select Set Mode Item “2 ARTS”. 3. Press the F key to enable adjustment of this Set Mode Item. FT-65R/FT-65E Advance Manual...
F key to save the callsign. 9. Press the PTT switch to save the new setting and return to normal operation. To monitor and check the entered callsign, repeat steps 1 - 6 above, then press the MONI/T.CALL key. FT-65R/FT-65E Advance Manual...
DTMF Operation The FT-65R/E keypad allows easy DTMF dialing for Autopatch, and repeater control purposes. Besides numerical digits [0] through [9], the keypad includes the [ ] and [ ] characters, plus the [A], [B], [C], and [D] tones often used for repeater control.
7. Release the PTT switch. The DTMF tone signals will continue to be transmitted until the number is completed. To change the DTMF Autodialer sending delay and speed, use the Set Mode Item “12 DTMF SET”. See page 36 for details. FT-65R/FT-65E Advance Manual...
6.25; 10; 12.5; 15; 20; 25; 50; or 100 kHz per step, as well as an automatic (“AUTO”) step selection based on the current operating frequency. The FT-65R/E is set up at the factory in the “AUTO” configuration, which probably is satisfactory for most operation. However, another step setting may be important to your operating requirements.
5. Press the PTT switch to save the setting and exit to normal operation. TX Battery Saver The FT-65R/E also includes a useful Transmit Battery Saver, which will automatically lower the power output level when the last signal received was very strong. For example, when operating in the immediate vicinity of a repeater station, there is generally no reason to use the High Power output in order to achieve full-quieting access to the repeater.
4. Press the [▲] or [▼] key to set the Time-Out Timer to the desired “Maximum TX” time (1 to 30 minutes, or OFF). The default setting is 3 minutes. 5. Press the PTT switch to save the new setting and return to normal operation. FT-65R/FT-65E Advance Manual...
In many areas of the world, channel congestion has required that operating channels be closely spaced. Closer channel spacing may require reduced deviation levels to preclude adjacent channel interference. To change the FT-65R/E TX deviation level, follow the below procedure: 1.
Inversion Scramble enabled, will not be able to clearly hear the conversation. To use this feature, the other (FT-65R/E) station must also complete the following procedure to set Inversion Scramble.
Cloning The FT-65R/E includes a convenient “Clone” feature, which allows the memory and configuration data from one transceiver to be transferred to another FT-65R/E. This can be particularly useful when configuring a number of transceivers for a public service operation. Here is the procedure for cloning data from one transceiver to another: 1.
Set (Menu) Mode Many FT-65R/E functions have already been described in previous chapters, The Set Mode Menu is used to configure the transceiver parameters, some of which have not been detailed previously. Use the following procedure to activate the Set Mode and configure the FT-65R/E function parameters: 1.
Page 37
S-1 / S-2 / S-3 / S-4 / S-5 / level. S-6 / S-8 / S-FULL / OFF 27 SCN.LAMP Enables/Disables the Scan lamp ON / OFF while paused. 28 SKIP Selects the Memory Scan “Skip” − − (SKIP SCAN) channel-selection mode. FT-65R/FT-65E Advance Manual...
Page 38
38 WX ALERT Enables/Disables the Weather Alert ALT.OFF / ALT. ON ALT.OFF Scan feature. 39 SCRAMBLE(*) Inversion scrambling (Encryption). SCRB.OFF/SCRB.ON SCRB.OFF : This function displays depending on the transceiver version. FT-65R/FT-65E Advance Manual...
Page 39
Copyright 2017 YAESU MUSEN CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of YAESU MUSEN CO., LTD. 1702-A...
Need help?
Do you have a question about the FT-65R and is the answer not in the manual?
Questions and answers
Factory reset
The provided context mentions that performing a factory reset on the Yaesu FT-65R can revert expanded TX settings, but it does not provide the exact steps for a factory reset. The manual reference suggests an "All Reset" procedure, which clears all settings, including passwords and memories. However, the exact steps to perform a factory reset are not detailed in the context.
This answer is automatically generated