Remotely Controlling Wireless Unit; Using An External Head Amp - Yamaha CL5 Reference Manual

Digital
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

Remotely controlling WIRELESS unit

This section explains how to remotely control a WIRELESS unit that's connected to the Dante
connector.
STEP
1. Press the WIRELESS tab in the upper part of the I/O DEVICE screen.
2. Press the I/O device displayed in the I/O DEVICE screen (WIRELESS page).
3. Set the output port on the OUTPUT PATCH window, as necessary.
Refer to step 7 in
"I/O device
patching"
I/O DEVICE screen (WIRELESS page)
1
2
1
Display switch buttons
Press one of these buttons to view the corresponding I/O
For more information about VIRTUAL/CONFLICT/DUPLICATE displayed below this
button, refer to (1) on P.154,
"I/O device
2
ID/Model name display
This shows the ID number, model name, and version of the I/O device.
(page
154).
3
device.
list."
3
DANTE SETUP button
Press this button to open the DANTE SETUP window, in which you can make settings
for the audio network.

Using an external head amp

If an I/O card (such as an MY16-ES64 card) supports the remote protocol of an external head
amp in the CL's slot, you will be able to remotely control from the CL console some
parameters of the external head amp (Yamaha SB168-ES or AD8HR), such as phantom
power (+48V) on/off status, gain, and HPF.
For details on the I/O card settings, refer to the Owner's Manual for the I/O card.
Connecting the CL series console to an AD8HR
To remotely control the AD8HR from the CL series console, install an MY16-ES64
EtherSound card in Slot 1 on the CL unit, then use an Ethernet cable to connect the CL unit
to the NAI48-ES. Then, connect the HA REMOTE connector on the NAI48-ES to the HA
REMOTE 1 connector on the AD8HR using an RS422 D-sub 9-pin cable. This connection
enables you to remotely control the AD8HR from the CL series console.
To transmit audio signals (input to the AD8HR) to the CL series console, connect the DIGITAL
OUT A (or B) connector on the AD8HR to the AES/EBU connector on the NAI48-ES using a
D-sub 25-pin AES/EBU cable. Signals will be sent or received between the NAI48-ES and the
CL series console via the MY16-ES64 card.
Alternatively, you can use a "daisy chain" connection to remotely control multiple AD8HR units
simultaneously. To do this, connect the AD8HR's HA REMOTE 2 connector to the second
AD8HR's HA REMOTE 1 connector. If you use the NAI48-ES, you can connect up to six
AD8HR units. In this case, to input AD8HR's audio signals into the CL series console, install
two MY16-EX cards on the CL unit since each slot on the CL unit accepts up to 16 channel
signals. Then, connect each two of the third and subsequent AD8HRs to each AES/EBU
connector using a D-sub 25-pin AES/EBU cable.
160
I/O devices and external head amps
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl1Cl3