PROBLEM
The Alenti lift raises or lowers after
the hand control button or the
control panel button is released.
The Alenti lift does not raise or
lower when the hand control button
or the control panel button is
pressed.
The Alenti lift functions only
operate with the use of the control
panel, not the hand control.
The Alenti lift raises and stops by
itself.
The Alenti lift is hard to manoeuvre. 1 Make sure that the brakes are released.
If the brakes are not functioning.
If the optional integrated scale is not
operating.
The scale is showing TILT.
The scale is showing no other error
codes than TILT.
It is only possible to lower the lift.
1 Pull the battery out and remove the patient from the Alenti lift.
2 Remove the hand control and put the battery back. If the failure is
gone, replace the hand control.
3 If the failure still occurs, contact qualified personnel.
1 Make sure the battery is connected correctly to the Alenti lift.
2 Make sure the battery has sufficient charge, the battery charger lamp
located on the Alenti lift turns green when the battery is fully charged.
3 Make sure the Alenti lift has not been lowered onto a fixed object.
If this occurs the automatic safety stop function will turn on.
4 Use the Emergency High/Low to remove patient from the Alenti lift.
Contact qualified personnel.
1 Make sure that the hand control connection is properly connected to
the socket.
2 If the problem persists, replace the hand control.
Make sure that the safe working load of 182 kg (400 lbs) is not exceeded.
The lowering function will still operate during this scenario.
2 Make sure that the castors roll and swivel freely. If not, remove the
patient from the Alenti lift and contact qualified personnel.
1 Make sure that the Alenti lift is flat on a levelled surface
(floor surface must not exceed a slope ratio of 1:50).
2 If the brake alarm sounds, try moving the Alenti lift to a flat levelled
surface and re-apply brakes. If the alarm continues, contact qualified
personnel.
1 Make sure the battery is connected correctly to the Alenti lift.
2 Make sure the battery has sufficient charge. The battery charger lamp
located on the Alenti lift turns green when the battery is fully charged.
3 If the problem persists, contact qualified personnel.
1 Make sure the Alenti lift is on a flat levelled surface.
2 If the problem persists, contact qualified personnel.
Contact qualified personnel.
The lifting device of this equipment is equipped with a a safety nut. If the
safety nut will be activated it will only be possible to lower the equipment
into a safe position. In case of this scenario stop using the equipment and
contact authorized service personnel for repair of the equipment.