Hitachi EH-150 Applications Manual page 170

Ethernet module 2 eh-eth2
Hide thumbs Also See for EH-150:
Table of Contents

Advertisement

Task
Subcommand
code
H10
Status
Memory status
Software version
CPU error code
Call CPU name
Undefined
None
H11
Stop designation
Run designation
Undefined
None
H16
Cancel occupancy
READ occupancy
WRITE occupancy
Occupancy mode
modification
(WRITE → READ)
Occupancy mode
modification
(READ → WRITE)
Undefined
H04, H07
None
H17
Forced cancel of all
peripherals
Forced cancel of local
station
Undefined
None
H18
Reading the calendar
clock
Setting the calendar
clock
response list by task code
Response task code
Code
H00
Normal execution
H01
Normal execution
H02
Normal execution
H03
Normal execution
H04
Normal execution
H05 to
Abnormal task code
HFF
Abnormal task code
H00
Normal execution
Not-executable
H01
Normal execution
Not-executable
H02 to
Abnormal task code
HFF
Abnormal task code
H00
Normal execution
H01
Normal execution
Not-executable
H02
Normal execution
Not-executable
H05
Normal execution
Not-executable
H06
Normal execution
Not-executable
H03,
Abnormal task code
to HFF
Abnormal task code
H00
Normal completion
H01
Normal completion
H02 to
Abnormal task code
HFF
Abnormal task code
H00
Normal execution
Not-executable
H01
Normal execution
Abnormal task code
Appendix B Task Codes Specifications
Return code
Code
H00
H00
H00
H00
H00
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H03
Operation error
H00
H03
Operation error
Combination error
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H00
H03
Occupancy code
mismatch
READ occupancy
maximum exceeded
Occupied by another
station
H00
H03
Occupancy code
mismatch
Occupied by another
station
H00
H03
Not occupied
H00
H03
Not occupied
Occupied by another
station
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H00
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H03
RTC cannot be
accessed
H00
H01
Abnormal number of
steps/words
B-45
Error cause
Code
H02
Undefined subcommand is set.
H05
Only the task code is input.
H0C
Setting is not in remote status.
Remote STOP is not enabled.
H0C
Setting is not in remote status.
CPU is in error status.
WRITE-occupied by other station.
Remote RUN is not enabled.
User-set run condition is not satisfied.
H0E
A RUN-prohibited task code has already
been executed and the CPU is in RUN-
prohibited state.
H02
Undefined subcommand is set.
H05
Only the task code is input.
H04
Local station is WRITE-occupying CPU.
H06
Already READ-occupied by the other
four stations.
H08
Another station is WRITE-occupying
CPU.
H03
Local station is READ-occupying CPU.
H08
CPU is occupied by another station.
H07
Local station is not occupying the CPU.
H07
Local station is not occupying the CPU.
H08
CPU is occupying by another station.
H02
Undefined subcommand is set.
H05
Only the task code is input.
H02
Undefined subcommand is set.
H05
Only the task code is input.
H10
Abnormal RTC, or not mounting
H05
Parameter length is too short.