A.1.2.4

Parameter setting menu

Display and settings
"P01" is displayed by default at first power-on only.
The last parameter you changed before power-off is displayed by default at the next power-on.
To change parameter settings, change the default setting of P01 first.
If the parameter value is changed without saving, after the enter button is pressed, menu display changes as follows:
The dot turns dark under the following circumstances:
At next power-on
After you have saved the value to the memory using the function of saving user parameters under Function menu
If the value of at least one parameter is changed without saving, after the mode selection button is pressed, menu
display changes as follows:
The dot turns dark under the following circumstances:
At the next power-on
After you have saved the value to the memory using the function of saving user parameters under Function menu
To fast increase the value, keep the UP button pressed for several seconds; to fast descrease the value, keep the
DOWN button pressed for several second.
Note
All parameter settings made under Parameter set menu are saved to RAM only. At next drive power-on, the settings made
are recovered to the setting prior to the last setting automatically. To save the setting permanently, use the function of saving
user parameters under Function menu.
For detailed description of individual parameters, see Section "SINAMICS V60 parameters (Page 427)".
Commissioning Manual
01/2017
475