Figure 5-2 Parameter Table For Setting Data - Siemens Siwarex U Device Manual

Universal weighing module for simatic s7 300 and et 200m
Hide thumbs Also See for Siwarex U:
Table of Contents

Advertisement

Bit
15 14 13 12 11 10 9
0
1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0
1
Figure 5-2
Parameter table for setting data
SIWAREX U
8
7
6
5
4
0
0
0
0
1
1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0
1
0
1
0
1
Meaning
3
2
1
0
Char. value of the load cell
≤ 1 mV/V
0
0
≤ 2 mV/V (default)
0
1
≤ 4 mV/V
1
0
Reserve
1
1
Decimal place for remote display
Decimal place 0 (default)
0
0
Decimal place 1
0
1
Decimal place 2
1
0
Decimal place 3
1
1
Decimal place 4
0
0
Decimal place 5
0
1
Filter setting
No filtering
Cutoff frequency: 5 Hz
Cutoff frequency: 2 Hz (default)
Cutoff frequency: 1 Hz
Cutoff frequency: 0.5 Hz
Cutoff frequency: 0.2 Hz
Cutoff frequency: 0.1 Hz
Cutoff frequency: 0.05 Hz
Mean value filter
No mean value filter (default)
Mean value filter switched on (30x20ms)
Memory goal
(only relevant for limit values and zero set value via
set to zero command)
Carry over into EEPROM (default)
Keep in RAM only
Operational state - channel
Channel switched on (default)
Channel switched off (default channel2 of U1)
Reserve
Weight unit
(only relevant for SIWATOOL, is only saved in SIWAREX U)
‚(default)
‚ g
‚ kg ‚
‚ t
‚ oz ‚
‚ lb ‚
, lbs‚
‚ kN ‚
Reserve
(Reserve, currently not used)
(default)
4BWEIGHING FUNCTIONS
5-29