Error Code Message Information
PSU0006
PSU0007
PSU0008
PSU0016
PSU0031
PSU1201
PSU1202
96
Downloaded from
www.Manualslib.com
Message
Power supply <
LCD Message
Power supply <
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review proper configuration in this manual.
Message Power supply <
number > is operating at 110 volts, and could cause a circuit breaker fault.
Details
A power supply that is designed to operate at 220V, but is connected to a 110V power
source requires additional current for operation. The additional current may trip circuit-
breakers or cause other electrical issues with the input source.
Action
Check input power source and cabling. Use recommended input power. Review this
Manual. If the issue persists, see
number > voltage rating does not match the system's requirements.
Message
Power supply <
Details
The system does not support mixed voltage power supplies.
Action
Install a power supply with the correct voltage rating.
Message
Power supply <
number > is absent. Check PSU.
LCD Message
PSU <
Details
The supply has been removed or has failed.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for damage.
3. If the issue persists, see
Message
Cannot communicate with power supply <
LCD Message Cannot communicate with PSU <
Details
The power supply may operate, however power supply monitoring will be degraded.
System performance may be degraded.
Action
Remove and reinstall the power supply. If the issue persists, see
Message Power supply redundancy is lost.
Details
The power supply will try to operate in a degraded state. System Performance and power
redundancy may be degraded or lost.
Action
Check input power. Reinstall the power supply. If the issue persists, see
Message Power supply redundancy is degraded.
Details
The power supply will try to operate in a degraded state. System Performance and power
redundancy may be degraded or lost.
manuals search engine
number > type mismatch.
number > is incorrectly configured. Check PSU.
Getting
Help.
number > is absent.
Getting
Help.
number >.
number >. Re-seat PSU.
Getting
Help.
Getting
Help.

Advertisement

Table of Contents
loading

Table of Contents