Error Code Message Information
CPU0801
CPU0802
CPU0803
CPU0804
76
Downloaded from
www.Manualslib.com
5. If the issue persists, see
number > voltage regulator module failed.
Message
CPU <
number > voltage regulator module failed. Re-seat module.
LCD Message
CPU <
Details
System performance may be degraded or the system may fail to operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
Message
A predictive failure detected on CPU <
Details
System performance may be degraded or the system may fail to operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
Message
The power input for CPU <
LCD Message
Lost power input for CPU <
Details
System performance may be degraded or the system may fail to operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
Message
The power input for CPU <
LCD Message The power input for CPU <
seat module.
Details
System performance may be degraded or the system may fail to operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
manuals search engine
Getting
Help.
Getting
Help.
number > voltage regulator module.
Getting
Help.
number > voltage regulator module is lost.
number >voltage regulator module. Re-seat module.
Getting
Help.
number > voltage regulator module is outside of range.
number > voltage regulator module is outside of range. Re-
Getting
Help.