Dell PowerEdge M420 Owner's Manual page 72

Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

Error Code Message Information
CPU0005
CPU0006
CPU0008
CPU0010
CPU0023
CPU0100
CPU0101
72
Downloaded from
www.Manualslib.com
3. If the issue persists, see
number > configuration is unsupported.
Message
CPU <
number > configuration is unsupported. Check CPU or BIOS revision.
LCD Message
CPU <
Details
System is unable to boot or may run in a degraded state.
Action
Review the technical specifcations for supported processor types.
Message Unrecoverable CPU complex error detected on CPU <
Details
System is unable to boot or may run in a degraded state.
Action
1. Turn system off and remove input power for one minute. Reapply input power and turn
system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see
Message
CPU <
number > is disabled.
Details
System is unable to boot or may run in a degraded state.
Action
If unexpected, check presence, and system setup (BIOS) configuration.
number > is throttled.
Message
CPU <
Details
The CPU is throttled due to thermal or power conditions.
Action
Review system logs for power or thermal exceptions.
number > is absent.
Message
CPU <
number > is absent. Check CPU.
LCD Message
CPU <
Action
Verify processor installation. If present, re-seat the processor.
Message
CPU <
number > temperature is less than the lower warning threshold.
Details
System performance may be degraded.
Action
Check system operating environment.
number > temperature is less than the lower critical threshold.
Message
CPU <
number > temperature is outside of range.
LCD Message
CPU <
Details
System performance may be degraded.
Action
Check system operating environment, fans, and heat-sinks.
manuals search engine
Getting
Help.
number >.
Getting
Help.

Advertisement

Table of Contents
loading

Table of Contents