13.3.2 PBX Configuration—[5-3-2] Optional Device—Voice
Message—DISA Message
Outgoing messages (OGM) for DISA calls can be specified. A maximum of 64 OGMs can be programmed.
To view a list of all programmed extension numbers and types, click Extension List View (see
6.4 Tool—Extension List View). To assign AA destinations easily, click Destination Setting (see
2.1.7 Extension Number Setting).
Floating Extension Number
Specifies the floating extension number of the OGM.
Default
OGM 01–64: 5801–5864
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
13.3.2 PBX Configuration—[5-3-2] Optional Device—Voice Message—DISA Message
Feature Manual References
14.1.2 OGM (Outgoing Message)
5.1.10 DISA (Direct Inward System Access)
7.1.5 Floating Extension
Name
Specifies the name of the OGM.
Default
OGM 01–64: DISA 01–DISA 64
Value Range
Max. 20 characters
Maintenance Console Location
13.3.2 PBX Configuration—[5-3-2] Optional Device—Voice Message—DISA Message
Feature Manual References
14.1.2 OGM (Outgoing Message)
5.1.10 DISA (Direct Inward System Access)
1 Digit AA Destination (Extension Number)—Dial 0–9
Specifies the destination for each DISA Automated Attendant (AA) number. After listening to an OGM, the