Note 5) Inverter trips with "E98", "E99" or hardware shutoff with "-S--".
External error detection is possible (E98).
Note 6) Inverter trips with "E99" or hardware shutoff with "-S--".
External error detection is invalid.
Note 7) Hardware shutoff with "-S--". Please check EDM externally.
Note 8) Inverter trips with "E99" or hardware shutoff with "-F01","-F02","-F01","-F02","-S--".
GS1 or GS2 delay detection is valid. EDM is checked inside.
Note 9) Hardware shutoff with "-F01","-F02","-F01","-F02" or "-S--".
GS1 or GS2 delay detection is invalid. Please check EDM externally.
・The following table shows the displayed when safe stopping .
Display of the operator
-F01
-F02
-F10
-F20
・The following table shows the safety action by GS1,GS2,EDM status and set point of b145.
E98 = Outside failure, E99 = Inside failure
GS1
Close
GS2
Close
EDM
Set 00
-
Set 01
-
Set 02
-
Set 03
-
Set 04
-
Set 05
-
Set 06
-
Safe stopping
-S--
Delay detection by the GS1 under running return
operation.
Delay detection by the GS2 under running return
operation.
Delay detection by the GS1 under safe stopping
operation.
Delay detection by the GS2 under safe stopping
operation.
Open
Close
Close
Open
Open
-
-
E37
E37
E98
E98
-
-
-
-
-F01
-F02
or
or
-F20
-F10
-F01
-F02
or
or
-F20
-F10
Description
Open
Close
Open
Close
-
-
E37
- - - -
E99
E99
E99
E99
-
-
E99
E99
-
-
109
Open
Close
Close
Open
Close (Act)
-
-
E37
E37
E99
E99
E99
E99
-
-
E99
E99
-
-
Open
(Shut Act)
Open
-
E37
-S--
-S--
-S--
-S--
-S--