Table of Contents

Advertisement

Solution-16/Solution-16 Safecom Quick Reference Guide
Location
428
Zone 12
0
(Default = Instant)
Zone
Type
Location
436
Zone 13
0
(Default = Instant)
Zone
Type
Location
444
Zone 14
0
(Default = Instant)
Zone
Type
Location
452
Zone 15
0
(Default = Instant)
Zone
Type
Location
460
Zone 16
0
(Default = Instant)
Zone
Type

Zone Types

Zone Type
0
Instant
1
Handover
2
Delay-1
3
Delay-2
4
Delay-3
5
Delay-4
6
Instant (Auto Isolated In STAY Mode 1)
7
Handover (Auto Isolated In STAY Mode 1)
Zone Options
Option
Description
1
Lockout Siren
2
Lockout Dialler
4
Silent Alarm
8
Sensor Watch
Zone Pulse Count
The pulse count allows you to program how many pulses (0 – 15) need to be registered within the pulse count
time to activate an alarm.
Zone Pulse Count Time
Option
0
0.5 Seconds
1
1 Second
2
2 Seconds
3
3 Seconds
4
4 Seconds
5
5 Seconds
6
10 Seconds
7
15 Seconds
Event Code
The three-digit event code is used to describe the zone function when reporting in Contact ID format (Eg.
Entry/Exit, Tamper, Perimeter etc). Refer to the installation manual for a full list of Contact ID codes available.
When the system is reporting in a format other then Contact ID, the event code are programmed as follows:
Hundreds Digit = Alarm Restore Report (0 = Alarm Restore Disabled)
Tens Digit = Alarm Report (0 = Alarm Disabled)
Units Digit = Channel Code (0 = Disabled)
429
430
0
0
Zone
Zone Pulse
Options
Count
437
438
0
0
Zone
Zone Pulse
Options
Count
445
446
0
0
Zone
Zone Pulse
Options
Count
453
454
0
0
Zone
Zone Pulse
Options
Count
461
462
0
0
Zone
Zone Pulse
Options
Count
Description
20ms Loop Response Time
Bosch Security Systems Pty Limited
431
432
0
1
Zone Pulse
Event Code
Event code
Count Time
Hundreds
Digit
439
440
0
1
Zone Pulse
Event Code
Event code
Count Time
Hundreds
Digit
447
448
0
1
Zone Pulse
Event Code
Event code
Count Time
Hundreds
Digit
455
456
0
1
Zone Pulse
Event Code
Event code
Count Time
Hundreds
Digit
463
464
0
1
Zone Pulse
Event Code
Event code
Count Time
Hundreds
Digit
Zone Type
8
Delay-1 (Auto Isolated In STAY Mode 1)
9
Delay 2 (Auto Isolated In STAY Mode 1)
10
Delay-3 (Auto Isolated In STAY Mode 1)
11
Delay-4 (Auto Isolated In STAY Mode 1)
12
24 Hour Burglary
13
24 Hour Fire
14
Chime
15
Not Used
Dialler Channel
Option
1
Group 1 (Area 1)
2
Group 2 (Area 2)
3
Group 3 (Area 3)
4
Group 4 (Area 4)
Option
150 ms Loop Response Time
8
20 Seconds
9
30 Seconds
10
40 Seconds
11
50 Seconds
12
60 Seconds
13
90 Seconds
14
120 Seconds
15
200 Seconds
433
434
435
3
0
1
Event Code
Dialler
Tens
Units
Channel
Digit
Digit
441
442
443
3
0
1
Event Code
Dialler
Tens
Units
Channel
Digit
Digit
449
450
451
3
0
1
Event Code
Dialler
Tens
Units
Channel
Digit
Digit
457
458
459
3
0
1
Event Code
Dialler
Tens
Units
Channel
Digit
Digit
465
466
467
3
0
1
Event Code
Dialler
Tens
Units
Channel
Digit
Digit
Description
Group
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution-16 safecom

Table of Contents