GE T60 Instruction Manual page 622

Transformer protection system ur series
Hide thumbs Also See for T60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 42 of 74)
ADDR
REGISTER NAME
7EAB
AG Loop Reactance
7EAD
AG Loop Impedance Magnitude
7EAF
AG Loop Impedance Angle
B
7EB0
BG Loop Resistance
7EB2
BG Loop Reactance
7EB4
BG Loop Impedance Magnitude
7EB6
BG Loop Impedance Angle
7EB7
CG Loop Resistance
7EB9
CG Loop Reactance
7EBB
CG Loop Impedance Magnitude
7EBD
CG Loop Impedance Angle
Neutral Overvoltage (Read/Write Grouped Setting) (3 Modules)
7F00
Neutral Overvoltage 1 Function
7F01
Neutral Overvoltage 1 Signal Source
7F02
Neutral Overvoltage 1 Pickup
7F03
Neutral Overvoltage 1 Pickup Delay
7F04
Neutral Overvoltage 1 Reset Delay
7F05
Neutral Overvoltage 1 Block
7F07
Neutral Overvoltage 1 Target
7F08
Neutral Overvoltage 1 Events
7F09
Neutral Overvoltage 1 Curves
7F0A
Reserved (8 items)
7F11
...Repeated for Neutral Overvoltage 2
7F22
...Repeated for Neutral Overvoltage 3
Auxiliary Undervoltage (Read/Write Grouped Setting) (3 Modules)
7F60
Auxiliary Undervoltage 1 Function
7F61
Auxiliary Undervoltage 1 Signal Source
7F62
Auxiliary Undervoltage 1 Pickup
7F63
Auxiliary Undervoltage 1 Delay
7F64
Auxiliary Undervoltage 1 Curve
7F65
Auxiliary Undervoltage 1 Minimum Voltage
7F66
Auxiliary Undervoltage 1 Block
7F68
Auxiliary Undervoltage 1 Target
7F69
Auxiliary Undervoltage 1 Events
7F6A
Reserved (7 items)
7F71
...Repeated for Auxiliary Undervoltage 2
7F82
...Repeated for Auxiliary Undervoltage 3
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 Modules)
7FA0
Auxiliary Overvoltage 1 Function
7FA1
Auxiliary Overvoltage 1 Signal Source
7FA2
Auxiliary Overvoltage 1 Pickup
7FA3
Auxiliary Overvoltage 1 Pickup Delay
7FA4
Auxiliary Overvoltage 1 Reset Delay
7FA5
Auxiliary Overvoltage 1 Block
7FA7
Auxiliary Overvoltage 1 Target
7FA8
Auxiliary Overvoltage 1 Events
7FA9
Reserved (8 items)
7FB1
...Repeated for Auxiliary Overvoltage 2
7FC2
...Repeated for Auxiliary Overvoltage 3
B-50
RANGE
-2147483647 to
2147483647
0 to 2147483647
-359.9 to 0
-2147483647 to
2147483647
-2147483647 to
2147483647
0 to 2147483647
-359.9 to 0
-2147483647 to
2147483647
-2147483647 to
2147483647
0 to 2147483647
-359.9 to 0
0 to 1
0 to 5
0 to 3.00
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 3
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 1
0 to 3
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 65535
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
ohm
1
F060
ohm
1
F060
degrees
0.1
F002
ohm
1
F060
ohm
1
F060
ohm
1
F060
degrees
0.1
F002
ohm
1
F060
ohm
1
F060
ohm
1
F060
degrees
0.1
F002
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F116
0 (Definite Time)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
---
1
F111
0 (Definite Time)
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
700
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents