User Manual
V5824G
11.3.2.8
To display the uplink MAC learning status of ONU, use the following command.
Command
show onu switch-control ONU-
ID
GPON Optic Module Threshold of ONU
The ONU's GPON optic module can operate depending on monitoring type of
temperature, RX/TX power, voltage or Txbias. To set the threshold of GPON optical
transceiver of ONU, use the following command.
Command
ani-rx-power
threshold
VALUE [high VALUE] | high
VALUE [low VALUE] }
ani-tx-power
threshold
VALUE [high VALUE] | high
VALUE [low VALUE] }
ani-temperature threshold {low
VALUE [high VALUE] | high
VALUE [low VALUE] }
ani-tx-bias
threshold
VALUE [high VALUE] | high
VALUE [low VALUE] }
ani-voltage
threshold
VALUE [high VALUE] | high
VALUE [low VALUE] }
Mode
Shows the uplink MAC learning status of ONU's uplink
GPON-OLT
port.
Mode
Configures the RX optical power threshold and sends
the configured threshold value to ONUs. The ONUs
{low
monitors the change of values and sends RX power
high/low alarm to OLT when the RX power exceeds the
threshold or it is below the threshold.
VALUE: RX power threshold value ( -127 to 0 dBm)
Configures the TX optical power threshold and sends
the configured threshold value to ONUs. The ONUs
{low
monitors the change of values and sends TX power
high/low alarm to OLT when the TX power exceeds the
threshold or it is below the threshold.
VALUE: TX power threshold value ( -127 to 0 dBm)
Configures the temperature threshold and sends the
configured threshold value to ONUs. The ONUs
monitors the change of values and sends temperature
ONU-Profile
high/low alarm to OLT when the temperature exceeds
the threshold or it is below the threshold.
VALUE: temperature threshold value ( -128∼127℃)
Configures the txbias threshold and sends the
configured threshold value to ONUs. The ONUs
{low
monitors the change of values and sends txbias
high/low alarm to OLT when the txbias exceeds the
threshold or it is below the threshold.
VALUE: tx-bias threshold value (0∼ 131 mA)
Configures the voltage threshold and sends the
configured threshold value to ONUs. The ONUs
{low
monitors the change of values and sends voltage
high/low alarm to OLT when the voltage exceeds the
threshold or it is below the threshold.
VALUE: voltage threshold value ( 0∼ 10.0 V)
UMN:CLI
Description
Description
529
Need help?
Do you have a question about the V5824G and is the answer not in the manual?
Questions and answers