5. Outing Function
Outing function is a function that prevents the room temperature from increasing too much (or
decreasing too much) when no one is in the room.

General Performance of the Outing Function

COOL / DRY
1 The air conditioner starts operation when the room
temperature increases up to -1°C of the upper
limit.
2 The air conditioner stops operation when the room
temperature decreases up to -2°C of the upper
limit.
HEAT
1 The air conditioner starts operation when the room
temperature decreases up to +1°C of the lower
limit.
2 The air conditioner stops operation when the room
temperature increases up to +2°C of the lower
limit.
[Precautions]
• The outing control only starts/stops the air conditioner. It does not change the operation mode/
temperature setting.
Therefore, the operation mode/temperature needs to be set beforehand so that the outing function
turns on the air conditioner with your desired operation mode/ temperature setting.
• If the room temperature rapidly changes, the room temperature may get over the upper or lower limit
when the outing function is activated.
• The outing function is invalid during FAN/AUTO operation mode.
• The air conditioner's stop order (stated in 2 ⁄ above) is valid only when the outing function is operated.
If operated using other remote control unit (or a centralized control device such as a system control),
the outing function does not work.
Outing function upper limit
Room temperature
Room temperature
Outing function Lower limit
EG-12