Installation Diagram Metpoint ® Ocv With Oil-Free Compression - Beko METPOINT OCV Installation And Operation Manual

Oil vapour measuring device with sampling probe
Table of Contents

Advertisement

Installation
10.4 Installation diagram METPOINT
1
Compressor with oil-free compression
2
Cyclone separator with BEKOMAT
3
Compressed-air tank
4
BEKOMAT for the tank drainage
5
Universal filter (G) with BEKOMAT
6
Minimum requirement: refrigeration dryer
7
Super-fine filter (S) with BEKOMAT
8
Sensor unit METPOINT
9
Evaluation unit with user interface (display) METPOINT
H1/H2
Shut-off valves of the measuring section
H3
Shut-off valve of the bypass
H4
Vent valve of the measuring section
The depicted installation shows the minimum requirement of the METPOINT
with oil-free compression. Other types of installation are possible (provided that they meet the defined operating
conditions).
For service measures, it is recommended to install a bypass at the METPOINT
components to be serviced in compressed-air systems.
Please observe that this bypass must also be free from oil and grease!
CAUTION!
Contaminated input air – inferior operating conditions!
When employing the METPOINT
damaged or destroyed!
24
®
OCV with oil-free compression
®
OCV
®
OCV under inferior operating conditions, the device can be contaminated,
®
OCV
®
OCV in combination with a compressor
®
OCV. This applies generally to all
METPOINT
®
OCV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents